![Meler Macro Series Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/meler/macro-series/macro-series_instruction-manual_1767094040.webp)
FOCKE MELER GLUING SOLUTIONS
4-8
MELTER OPERATION
The value shown corresponds to the percent decrease in the real
temperature compared to the set point temperature that will occur
when this function is activated.
7. Use the right arrow to go to the next display where delay time value
appears.
8. Use the up-down arrow to select the desired value (between 0 and 60
min).
9. Use the right arrow to advance to the next screen, where the level
detector activation/deactivation is found.
10. Use the up-down arrow to select the desired value (ON/OFF). When
OFF is selected, neither the on-screen display nor the external signal
activation will be operational. If ON is selected, when the level of hot-
melt is low the alarm (n - - - ) will be displayed on the screen and the
external signal contact will be activated.
11. Use the right arrow to return to the initial parameter.
12. For any parameter, the left arrow may be used to exit the special menu
and display the tank temperatures once again.
To record any parameter, you must always move to the next parameter, using
the right arrow.
Setting the clock
Macro system series melters are equipped with a weekly programmable
system controlling equipment connection and disconnection and activating
and deactivating the standby function.
Before programming these functions, it is necessary to introduce into the
control unit data corresponding to the day and hour used to execute these
programs.
Programming the current day and hour
1. Press the button with the clock symbol.
A ‘0’ will appear on the display, indicating the program for current day
and hour information.
2. Press the button with the clock symbol once again.
o f f
o f f
nn
- - -
- - -
nn
1 0
1 0
ƒƒ
1 6 0
1 6 0
1 6 0
1 6 0
0
0
Содержание Macro Series
Страница 1: ...MA 5052 ENG 221220 GLUING SOLUTIONS ADHESIVE MELTER MACRO SERIES INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 16: ...FOCKE MELER GLUING SOLUTIONS 2 4 INTRODUCTION Main components 10 10 12 14 13 11 15 1 2 3 7 6 8 9 4 5 5 ...
Страница 32: ...FOCKE MELER GLUING SOLUTIONS 3 12 INSTALLATION This page is intentionally left blank ...
Страница 58: ...FOCKE MELER GLUING SOLUTIONS 4 26 MELTER OPERATION This page is intentionally left blank ...
Страница 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 6 4 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 71: ...ELECTRICAL DRAWINGS 7 1 MA 5052 ENG MACRO SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...