4-5
MELTER OPERATION
MA-5052-ENG
MACRO SERIES MELTER MANUAL
Alarm displays
Macro series melter equipment tell the user when a malfunction has occurred
in the unit, sending warning messages that may be seen on the control panel
display.
When an alarm appears, the control unit takes a series of steps to protect the
unit. Simply correct that malfunction and the control unit will reactivate the
equipment functions.
Standby function does not generate any alarm.
If a temperature sensor is broken, the system heats all the elements except
the one where the failure is located.
In case of overheating the system cuts off inmediately the damaged element.
After three minutes if the failure continues all the system will be shut down.
After repairing the failure the system starts heating normally.
Code
Source
Actions
Heating
Pump
Main machine signal
Err 0
tank broken sensor
only tank off
off
off
Err 1
distributor1 broken sensor
only distributor1 off
off
off
Err 2
distributor2 broken sensor
only distributor2 off
off
off
Err 3
distributor3 broken sensor
only distributor3 off
off
off
Err 4
distributor4 broken sensor
only distributor4 off
off
off
Err 5
hose1 broken sensor
only hose1 off
off
off
Err 6
applicator1 broken sensor
only applicator1 off
off
off
Err 7
hose2 broken sensor
only hose2 off
off
off
Err 8
applicator2 broken sensor
only applicator2 off
off
off
Err 9
hose3 broken sensor
only hose3 off
off
off
Err 10
applicator3 broken sensor
only applicator3 off
off
off
Err 11
hose4 broken sensor
only hose4 off
off
off
Err 12
applicator4 broken sensor
only applicator4 off
off
off
Err 13
premelter broken sensor
only premelter off
off
off
Err 100
tank overheating
all components off
off
off
Err 101
distributor1 overheating
all components off
off
off
Err 102
distributor2 overheating
all components off
off
off
Err 103
distributor3 overheating
all components off
off
off
Err 104
distributor4 overheating
all components off
off
off
Err 105
hose1 overheating
all components off
off
off
Err 106
applicator1 overheating
all components off
off
off
Err 107
hose2 overheating
all components off
off
off
Err 108
applicator2 overheating
all components off
off
off
Err 109
hose3 overheating
all components off
off
off
Err 110
applicator3 overheating
all components off
off
off
Err 111
hose4 overheating
all components off
off
off
Err 112
applicator4 overheating
all components off
off
off
Err 113
premelter overheating
all components off
off
off
Содержание Macro Series
Страница 1: ...MA 5052 ENG 221220 GLUING SOLUTIONS ADHESIVE MELTER MACRO SERIES INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 16: ...FOCKE MELER GLUING SOLUTIONS 2 4 INTRODUCTION Main components 10 10 12 14 13 11 15 1 2 3 7 6 8 9 4 5 5 ...
Страница 32: ...FOCKE MELER GLUING SOLUTIONS 3 12 INSTALLATION This page is intentionally left blank ...
Страница 58: ...FOCKE MELER GLUING SOLUTIONS 4 26 MELTER OPERATION This page is intentionally left blank ...
Страница 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 6 4 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 71: ...ELECTRICAL DRAWINGS 7 1 MA 5052 ENG MACRO SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...