4-3
MELTER OPERATION
MA-5127-ENG
MACRO FOAM SERIES MELTER MANUAL
While the system is running the delay timer both LEDs remains blinking until
the programmed time value has been reached. If then, any other element has
not reached 3° below its temperature setting point, the LEDs turn off.
If the system is shut down, for any possible mode, when it is turning on the
delay timer only starts again if the tank temperature is 20° below setting
point.
3. Make sure that the control switches for each pumping control cards
installed are in the correct positions (see Chapter ‘2. Introduction.
Operating modes’).
Melter equipment displays
Macro Foam system series melters have two displays built into their control
panel, with three sets of 7 segments each for displaying the temperature
values (set point and real temperature), programmable parameters and
alarms.
They are equipped with LED indicators to display the heating of each
component, as well as the pump activations and the main machine connection
signal.
They are also equipped with LEDs indicating equipment connection/
disconnection and standby function connection/disconnection:
LED display
Component heating
Component status
constantly lit
constant
low temperature
blinking slowly
as need (according to PID parameters) temperature near set point
blinking rapidly
programming or display
change in set point values
off
not heating
temperature reached
LED display
On/off
Standby
constantly lit
turned off unit
function activated
blinking slowly
deactivation programmed for the
current day
activation programmed for the
current day
blinking rapidly
activation/deactivation
programming mode
activation/deactivation
programming mode
off
unit in operation
function deactivated
simultaneous intermittence from leds of
pump activation and main machine signal timing in progress, once the tank has reached its set point temperature
1 5 7
1 5 7
1 6 0
1 6 0
Содержание MACRO FOAM Series
Страница 1: ...MA 5127 ENG 231220 GLUING SOLUTIONS ADHESIVE MELTER MACRO FOAM SERIES INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 34: ...FOCKE MELER GLUING SOLUTIONS S A 3 14 INSTALLATION This page is intentionally left blank ...
Страница 75: ...ELECTRICAL DRAWINGS 7 1 MA 5127 ENG MACRO FOAM SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 76: ...FOCKE MELER GLUING SOLUTIONS S A 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 78: ...FOCKE MELER GLUING SOLUTIONS S A 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...