2-19
MA-5247-ENG
ARION HOSES. INSTALLATION TECHICAL GUIDE
HOSES SETUP AND CONNECTION
Warning:
Hot zone with high temperatures. Risk of burns. Use thermal
protective equipment.
1.
Heat the hose to ‘Standby’ temperature.
2. Depressurize the system and disconnect the hose.
3. If possible, allow as much adhesive as possible to drain from inside the
hose.
4. Loosen the set screws of the removable racord.
5. Using two spanners, loosen the removable racord at the end of the
hose.
6. Loosen the set screws from the fixed racord at the other end of the
hose and remove the core hose.
7. Insert the new core hose and tighten the set screws of the fixed
racord.
8. Using two spanners, mount the removable racord at the end of the
hose and tighten the set screws.
REMOVABLE CORE HOSE REPLACE
ARION CIRCLE
REMOVABLE RACORD
FIXED RACORD
CORE HOSE
SET SCREWS
CORE HOSE
REMOVABLE RACORD