Needle Case Removal
•
This repair requires timing and other adjustments and should be done by an authorized service
technician.
CAUTION!!
DO NOT disassemble the needle case any further than what is provided in this man-
ual. If you do so, the alignment of the needle case will be severely compromised and extremely
difficult to reset without the proper fixtures used at the factory.
Figure 1 - Needlecase Assembly
1. Turn ON the machine and open the Bravo OS. Click on “Tools>Maintenance” menu and then
“Head Timing” tab. Click on the “Head Up” button to bring the head to the HEAD UP position.
If the machine is jammed or will not go to the head up position, contact Technical Support for
instructions.
2. Color change to either Needle 5 or 6.
3. Engage the emergency stop by pressing in.
WARNING! Do not proceed without engaging the emergency stop button or by turning the
machine off. The machine may begin operating if you do not do so. This can result in severe
damage to the machine and/or personal injury. You do not need to disconnect the power input
cord from the machine.
4. Take the small access cover off the needle case assembly.