10 Settings
61
Explanation of the slide show options
Display duration per
image
Indicates the time in seconds between the display of two separate pictures.
Waiting time
Indicates how long the display remains in normal mode before the slide show
starts.
Activated
Setting/unsetting the checkmark activates/deactivates the screensaver.
Log printer MELAprint 42/44
If you wish to output the sterilization log via the log printer MELAprint 42/44, you need to set this on the
steam sterilizer once. The operation manual of the log printer indicates how to set it up.
Label printer MELAprint 60
If you wish to output the sterilization logs via the label printer MELAprint 60, you need to set this on the
steam sterilizer once. The operation manual of the label printer indicates how to set it up.
Sensitivity
1.
Select
Settings
>
Touchscreen sensitivity
.
The display switches to the settings window.
2.
You can determine the pressure required to
activate a pushbutton. using the
and
pushbuttons.
3.
Accept all the settings with SAVE and then leave
the menu.
Energy-saving mode
If the steam sterilizer is not be switched off during longer operating pauses, it can be operated in energy-
saving mode. This reduces the time which is required in order to pre-heat the double-jacket steam genera-
tor to the necessary start temperature after deactivation. Two waiting times can be set in energy-saving
mode:
Waiting time 1 (W1)
After a pre-set waiting time of 15 min, the temperature of the double-jacket steam
generator will sink to 103°C. The program run time becomes approx. 2 min longer upon the next start.
Waiting time 2 (W2):
After a pre-set waiting time of 60 min, the double-jacket steam generator is no
longer heated. Accordingly, the length of the program run time increases by about 5 min upon the next
start, depending on the length of the operating pause, as the double jacket steam generator must first be
pre-heated to the necessary start temperature.
Setup of the energy-saving mode is described here: