M2i-LAN Laser-Scanner manual
HB-M2-iLAN-UDP-E.doc
page 28 of 44
MEL Mikroelektronik GmbH, Breslauer Str. 2, 85386 Eching / Germany
www.MELSensor.de
Step
Action
Remarks
1
Connect the Scanner
Power = off
2
Connect RS-232 to Com-1
Baudrate of PC Com-1 = 115.200
3
Power up the Scanner
Press and hold the Prog switch* for 1 second while you switch power
on
4
The scanner enters Prog mode
5
With start.bat launch the Flash-
Tool “Flashm16.exe”
Before launching check start.bat with a text editor
Use start.bat to launch the Flash-Tool.
The upload speed is 57.600 Baud, Baud rate adjusts automatically
6
Wait until Flashing END
This may take a few minutes!
7
Close Flash Tool
8
Normal
operation
* The Prog. switch connects Sync-Out to Digital Input 1
A service adapter is available as
special accessory
from MEL,
see page 7: M2-RS-232 ProgBox.
U
U
p
p
d
d
a
a
t
t
i
i
n
n
g
g
(
(
F
F
l
l
a
a
s
s
h
h
i
i
n
n
g
g
)
)
o
o
v
v
e
e
r
r
t
t
h
h
e
e
E
E
t
t
h
h
e
e
r
r
n
n
e
e
t
t
The Controller-Firmware of the Scanners can be
uploaded through the Ethernet connection.
Use the MEL configuration software Ethernet-
Scanner-2009 (Release date 26.Jan.2009) and
have a
valid
Firmware file for the version of scanner
hardware in use. The prog switch must be set as
described in the chapter before.
In the configuration software Tab 15 is selected,
with the button
Datei flashen
and „Open“ the
firmware file is selected.
The Firmware-File defines, which IP Address the
scanner will have after the flash process, when the
option “
IP-Reset“
is activated. Please note: the IP
address defined by the firmware file can be set only
by MEL.
When the option IP-Reset is not activated, the IP-
Address of the scanner remains unchanged.
After uploading of the Firmware you can change the
IP Address of the Scanner with the Web Browser.
How to proceed:
1. open EthernetScanner-2009 - Tab 15
2. load Firmware file: click „Open”
3. Wait until file has loaded
4. click
„Flash“
5. Wait until „Flashing END“ appears.
While the Flashing process is active, do not switch
off the scanner – this will ruin the programming and
render the scanner to a status where further
programming is not possible.
The FPGA Firmware can be uploaded with an
internal connector inside the scanner head. This
upload procedure can be made only at the
headquarter at MEL in Eching / Germany.