6.4 XHE-REL Error Relay
Error Output:
Relay A:
PWR 1
Relay B:
PWR 2
Relay C:
Rubidium
If the Rubidium module is synchronous to the source, the relay
is switched to NO (Normaly Open) mode. In the event of an error,
the relay switches to NC (Normaly Closed).
Technical Specifications Error Relay:
Switching Voltage:
220 V DC
max
/ 250 V AC
max
Switching Load:
60 W
max
/ 62.5 VA
max
UL/CSA:
0.3 A
125 V AC
0.3 A
110 V DC
1 A
30 V DC
Response Time:
ca.3 ms
—————————————————————–
Status-LEDs
St:
blue - during initialization
green - normal operation
A:
green - PWR 1 OK
red - PWR 1 not connected
B:
green - PWR 2 OK
red - PWR 2 not connected
C:
green - Rubidium in normal operation
rot - Error (event notification)
XHE-REL
CO NO NC
CO NO NC
CO NO NC
A
B
C
14
Date: 28th July 2020