6.2 AC/DC Power Connector
Connector Type:
5-pol. DFK
Status-LED:
green - Power On
∆
V1:
Potentiometer for adjusting
the output voltage (24 V)
*
Pin Assignment:
1: N/-
2: not connected
3: PE (Protective Earth)
4: not connected
5: L/+
Input Parameter
——————————————————————————–
Nominal Voltage Range:
U
N
=
100-240 V
∼
100-240 V
Maximum Voltage Range:
U
max
=
90-264 V
∼
100-250 V
Nominal Current:
I
N
=
0.40 A
∼
Nominal Frequency Range:
f
N
=
50-60 Hz
Maximum Frequency Range:
f
max
=
47-63 Hz
Inrush Current:
I
P
=
20 A @ 230 V AC
Output Parameter
—————————————————————————————————
Maximum Power:
P
max
=
50 W
Maximum Heat:
P
therm
=
180.00 kJh (136.49 BTU/h)
—————————————————————————————————
* Attention:
The output voltage
∆
V1 of the power supply unit is set at
the factory and must not be changed afterwards. If the power supply
unit malfunctions, please contact the Meinberg Technical Support.
V1