5 microSync HR100/DC Connectors
5.9 DMC X2 Terminal Connector
Note:
The connector on the device side and the connection socket of the X2 terminal are provided with coding
pins to avoid confusion with the X1 connection terminal.
Pin 1
PP 5+
programmable pulse (optocoupler)
Pin 2
PP 5
programmable pulse (RS-422A)
Pin 3
PP 5
programmable pulse (RS-422B)
Pin 4
PP 6
programmable pulse (RS-422A)
Pin 5
PP 6
programmable pulse (RS-422B)
Pin 6
+ TC In
Time Code DCLS (TTL, isolated)
Pin 7
+ TCA
*
Out
Time Code DCLS (TTL, isolated)
Pin 8
- TCA Out
Time Code DCLS (TTL, isolated)
TTL active high 250mA,
short circuit proof
* TCA
= Time Code Amplified, DCLS output
with large output current.
Pin 9
PP 5-
program. pulse (optocoupler)
Pin 10
GND
ground
Pin 11
GND
ground
Pin 12
GND
ground
Pin 13
GND
ground
Pin 14
- TC In
Time Code DCLS (TTL, isolated)
Pin 15
not used
Pin 16
not used
Status-LEDs:
PP 5 . . . PP 8
Status of Pulses Out
9
8
16
1
9
8
16
1
To the X2 device connection
16-pin socket with retaining clip
Cable inlet side
Status
PP
5
6
7
8
Scheme Terminal assignment
Programmable output PP 5
DC-insulated by optocouplers
U
CEmax
= 55 V
I
Cmax
= 50 mA
P
tot
= 150 mW
Response time
Turn on Time: typ. 5
µ
s, max. 9
µ
s
Turn off Time: typ. 10
µ
s, max. 70
µ
s
Standard (Opto Coupler)
Channel 5
PP 5
PP 5 +
Pulse generator
microSync
Date: January 7, 2022
21
Содержание microSync HR100/DC
Страница 1: ...TECHNICAL REFERENCE microSync HR100 DC January 7 2022 Meinberg Funkuhren GmbH Co KG ...
Страница 2: ......