6.2 Fuse
The fuse protects against overload or short circuits and thus prevents damage to the installed
power supply. The fuse is accessible from the front panel and can be replaced.
Technical Specification
————————————————————
Rated Voltage:
250 V
Shutter delay:
slow blow
Rated Current:
1.6 A
————————————————————
WARNING!
This equipment is operated at a hazardous voltage.
serial interfaces from the device.
- Disconnect all signal lines such as, antenna, fault message relay contact and
- Please note the information in the chapter:
„
Important Safety Instructions -> Fuse Replacement“
Danger to life due to electrical shock!
- Disconnect the device from the mains! To do this, press the disconnector.
Then, loosen the locking screws of the supply plug (if present) and pull it off.
6.3 GPS180 Status LEDs
LED Indicators
Fail:
red: time has not synchronized
Ant.:
red: antenna faulty or not connected
Nav.:
green: positioning successfully
Init:
blue: while the receiver passes through
the initialization phase
green: the oscillator has warmed up
Fail
Ant.
Nav.
Init
22