Meinberg IMS SCG180-U Скачать руководство пользователя страница 1

MANUAL

IMS SCG180-U Setup Guide

Hot-Plug Module

7th June 2018

Meinberg Funkuhren GmbH & Co. KG

Содержание IMS SCG180-U

Страница 1: ...MANUAL IMS SCG180 U Setup Guide Hot Plug Module 7th June 2018 Meinberg Funkuhren GmbH Co KG ...

Страница 2: ......

Страница 3: ...ggable Modules 2 2 1 Additional Safety Hints 3 2 2 Supply Voltage 3 2 3 Cabling 4 3 Replacement or Installation of a Hot pluggable IMS Module 5 4 SCG U Studio Clock Generator 6 4 1 SCG U Configuration via Web Interface 7 Date 7th June 2018 IMS SCG180 U Setup Guide ...

Страница 4: ...Funkuhren GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Internet https www meinbergglobal com Mail info meinberg de Date 2016 01 14 IMS SCG180 U Setup Guide Date 7th June 2018 1 ...

Страница 5: ...ck to the manufacturer for maintenance Exchange of hot swap components Ensure that components which will be replaced during operation always be treated with the utmost care Avoid contact with live components Electrostatic discharge can damage electronic components For this reason ensure protection against electrostatic discharges by wearing anti static shoes while working with the system Take care...

Страница 6: ...ion of high voltage devices 2 2 Supply Voltage WARNING This device is powered by a dangerous voltage Nonobservance of the safety instructions of this manual may lead to serious damage to persons and property and to danger to life Installtion commissioning maintenance and operation of this device are to be carried out by qualified personnel only The general safety instructions and standards e g IEC...

Страница 7: ...er work done the connectors particularly when connectors are opened may never be carried out when the installation is energized All connectors must be covered to prevent from accidental contact to life parts ALWAYS ENSURE A PROPER INSTALLATION 4 Date 7th June 2018 IMS SCG180 U Setup Guide ...

Страница 8: ... anchored in the connector block of the housing You need a certain amount of force to release the module from this link Once the connection to the connector block of the system s backplane is loosened the module can be easily pulled out 3 When installing the new IMS module please ensure that the board is correctly inserted into the two guide rails of the system housing Non observance can cause dam...

Страница 9: ...provides four outputs with different frequencies The SCG provides a wide range of programmable word clock rates between 24Hz 12 288MHz Technical Specifications Outputs 4 x BNC 2 5V TTL into 75 Ohm outputs with configureable frequencies Input Signal 10MHz sinewave or square pulse Current Consumption 5 V 5 400 mA Ambient Temperature 0 50 C 32 122 F Humidity 85 max 6 Date 7th June 2018 IMS SCG180 U S...

Страница 10: ...put 3 In the IO Configuration menu each output frequency can be adjusted seperately In the figure above the following value is set Frequency Out 3 Base Frequency Scale Frequency Out 3 44 1 kHz 1 4 Frequency Out 3 11 025 kHz Overview Configuration SCG U Sound Clock Generator Outputs 1 4 Output Type Studio Clock Out State Disabled Enabled Base Frequency 32kHz 44 1kHz 48kHz Scale 1 8 to 256 IMS SCG18...

Страница 11: ......