5.4.12 BPE - Backplane Port Expander
Output Signals:
fixed:
10 MHz, PPS, IRIG DCLS, IRIG AM, 2.048 MHz,
PPOs (selectable via receiver)
Power Requirements:
5 V +-5%, 150 mA / BNC
5 V +-5%, 150 mA / FO
Status Indicators
LED St:
BPE status
LED In:
Status of the backplane’s output signals
LED A:
BPE status - output signals (1 + 2)
LED B:
BPE status - output signals (3 + 4)
Initialisation:
LED St: blue until USB is configured
LED In - LED B: off until USB is configured
USB is configured:
LED St: blue
LED In - LED B:
0,5 sec. red -> 0,5 sec. yellow ->
0,5 sec. green -> 0,5 sec. off
Normal Operation:
LED St. + LED In: green
LED A: green, if the desired signal is present
on output 1 and output 2
LED B: green, if the desired signal is present
on output 3 and output 4
Fig. right: BPE signal outputs
BPE-1040 with 4 x BNC (Out 1 - Out 4) and
BPE-2000 with 4 x BNC (Out 1 - Out 4) and
BPE-8200 with 2 x BNC (Out 1/2) und 2 x ST FO
40
Date: 20th April 2021