background image

4 Important Safety Information

Please ensure that IMS modules designed for "hot-plugging" (modules that are removable and insertable while
a system is in operation) are always handled with the utmost care.

Before performing any maintenance work on the system, Meinberg recommends:

backing up stored configurations (e.g., via USB flash drive or the Web Interface)

taking note of the chapter "Prevention of ESD Damage".

taking note of the chapter "Power Supply".

4.1 Product Documentation

Detailed product documentation is provided on a USB flash drive delivered with the Meinberg system. The
manuals can also be downloaded from the Meinberg website at https://www.meinbergglobal.com, where you can
enter your system name into the search box at the top of the page to find the relevant manual. Alternatively,
contact Meinberg Support for further assistance.

The "Docs & Support" menu on the Web Interface also provides user manuals for time server administrators.

This manual contains important safety instructions for the installation and operation of the
device. Please read this manual thoroughly before using the device.

This device may only be used for the purpose described in this manual. In particular, the
specified operating limits of the device must be heeded. The person setting up the device is
responsible for safety matters in relation to any larger system in which the device is
installed!

Failure to observe these instructions may have an adverse impact on device safety!

Please keep this manual in a safe place.

Target Readership

This manual is only intended to be used by qualified electricians, or by persons who have been appropri-
ately instructed by a qualified electrician and who are familiar with applicable national standards and with
safety rules & regulations. This device may only be installed, set up, and operated by qualified personnel.

4

Date: June 16, 2022

IMS-GPS182

Содержание IMS-GPS182

Страница 1: ...SETUP GUIDE IMS GPS182 Hot Plug Module June 16 2022 Meinberg Funkuhren GmbH Co KG...

Страница 2: ......

Страница 3: ...Antenna 15 9 System Installation 20 9 1 Important Information Regarding Hot Pluggable IMS Modules 20 9 2 Installation of Hot Pluggable IMS Modules 21 9 3 Data and Signal Cables 22 10 Configuration and...

Страница 4: ...uhren GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Website https www meinbergglobal com Email info meinberg de Date March 8 2022 Manual Version 1...

Страница 5: ...2 Change Log Version Date Revision Notes 1 0 02 15 2022 Initial version 2 Date June 16 2022 IMS GPS182...

Страница 6: ...ut modules generate a wide variety of specific output signals used in a diverse range of applications Use of Two IMS GPS182 Modules In systems equipped with two IMS GPS182 modules an RSC switchover mo...

Страница 7: ...ance The Docs Support menu on the Web Interface also provides user manuals for time server administrators This manual contains important safety instructions for the installation and operation of the d...

Страница 8: ...urn be attached to an uncoated non conductive metal part of the system Use only tools and devices that are free of static electricity When transporting devices Devices must only be touched or held by...

Страница 9: ...can lead to an explosion or to a leakage of flammable liquids or gases Never short circuit the battery Never attempt to recharge the battery Never throw the battery into a fire The battery must only b...

Страница 10: ...gurations saved for the reference clock may be lost 4 5 Cabling WARNING Danger of death from electric shock Never work on cables while the power is live Always disconnect the cables from the devices a...

Страница 11: ...are used in applications where the IMS system is to be integrated with an XHERb system for high accuracy holdover synchronization performance Left to right GPS182 4 HP standard model GPS182 4 HP with...

Страница 12: ...hnical specifications Electrical Connector 96 Pin DIN 41612 Connector Operating Voltage 5 V DC Current Draw approx 100 mA depending on the used oscillator Temperature Range 0 50 C Relative Humidity Ma...

Страница 13: ...6 IMS GPS182 Module Connectors and LEDs 1 2 4 3 Note The numbering in the drawing above relates to the relevant subsection in this chapter 10 Date June 16 2022 IMS GPS182...

Страница 14: ...nal operating system has initialized the clock and the oscillator is warmed up Nav LED Navigation Status Shows the status after initialization by the operating system Green not flashing Geolocation vi...

Страница 15: ...Connection Type D Sub Male 9 Pin Cable RS 232 Cable Shielded 1 5 6 9 6 3 XHE SPI Pin Assignment of the optional XHE SPI Connector A1 PPS In A2 PPS Out Pin 1 SCL_Out SPI Clock Pin 2 CS Chip Select Pin...

Страница 16: ...er Requirements of the Antenna 15 V 100 mA Via Antenna Cable Connection Type BNC Female Type N Female Cable Type Coaxial Cable Shielded Cable Length Max 300 m to RG58 Max 700 m to RG213 Antenna GNSS I...

Страница 17: ...ntact Meinberg immediately Only the recipient the person or company receiving the system may file claims or complaints against the forwarder for damage caused in transit Meinberg recommends that you k...

Страница 18: ...lines and electrical substations Selecting the Antenna Location To avoid difficulties with synchronization select a location that allows for an unobstructed view of the sky so as to ensure that enoug...

Страница 19: ...building Case Example 2 In the event of a direct lightning strike on the antenna the resultant transient voltage may be discharged via the PE busbar GNS L1 antenna only This prevents the transient vo...

Страница 20: ...actor 2 Voltage surges e g caused by lightning strike may be transmitted along the antenna cable and cause damage to the receiver Using a MBG S PRO surge protector can help to protect your receiver ag...

Страница 21: ...tor female con nector Grounding Conductor Conductor of diameter approx 1 5 mm attached to surge protector As short as possible to Grounding Busbar 4 The next step is to connect the supplied coaxial ca...

Страница 22: ...l Propagation Delay in the Antenna Cable To enable the connected receiver to compensate for the signal propagation delay inherent in the antenna cable you will need to enter either the length of your...

Страница 23: ...cing it in order to keep your system on I O ESI and MRI Slots Hot Pluggable CLK1 CLK2 Hot Pluggable When a clock module is replaced or installed it is important to Slots rescan the reference clocks Re...

Страница 24: ...s The module must be pulled carefully out of the guide rail Note that the module will be securely seated in the connector block inside the chassis a certain amount of force must be applied to release...

Страница 25: ...follows the RS 232 standard and thus it is generally possible to use any standard pre fabricated RS 232 cable of suitable quality D Sub 9 to D Sub 9 D Sub 9 to D Sub 25 if the receiving device posses...

Страница 26: ...connected reference clock to compensate for the cable induced propagation delay of the sig nal you must either specify the length of the antenna cable in meters antenna Meinberg system or enter the o...

Страница 27: ...erence source so that it can be used to synchronize the system Illustration MRS Configuration Selection and Prioritization of the Available Reference Sources 1 Select the menu Clock State Configuratio...

Страница 28: ...on of the receiver has changed by several hundred miles since the last time the system was on the elevation and Doppler shift of the satellites will not match the calculated values This will cause the...

Страница 29: ...em The firmware of your IMS system may not be up to date Check in the menu System Configuration Firmware Mangement whether the latest version of LANTIME OS is installed and in stall the latest version...

Страница 30: ...12 Technical Appendix GPS Antenna Accessories 12 Technical Appendix GPS Antenna Accessories Physical Dimensions IMS GPS182 Date June 16 2022 27...

Страница 31: ...andwidth 9 MHz Frequencies Mixed Frequency 10 MHz IF frequency 35 4 MHz Connector Type N Female Form Factor ABS Plastic Case for Outdoor Installation IP Rating IP66 Humidity 95 Temperature Range 60 C...

Страница 32: ...a sheet of the cable in question for further specifications 12 2 Antenna Short Circuit Information This information only applies to devices with a front display If the antenna line is short circuited...

Страница 33: ...BB is equipped with two Type N female connectors and has no dedicated input output polarity and no preferred installation orientation Phoenix CN UB 280DC BB Features High RF Performance Multiple Stri...

Страница 34: ...ric Shield Typically 1 5 pF Surge Current Resistance Core Earth C1 1 kV 500 A C2 10 kV 5 kA C3 100 A D1 2 5 kA Ambient Temperature During Operation 40 C 80 C Supported Altitude 2000 m above sea level...

Страница 35: ...12 3 1 MBG S PRO Physical Dimensions 67 11 15 8 25 13 4 12 3 2 Installation and Grounding 32 Date June 16 2022 IMS GPS182...

Страница 36: ...orizon given a specific location and time Each satellite transmits its own ephemeridal schedule as well as the almanacs of all existing satellites Satellite Systems GPS was installed by the United Sta...

Страница 37: ...the international UTC timescale Coor dinated Universal Time when the satellite system became operational in 1980 Since it has entered service however several leap seconds have been introduced to the...

Страница 38: ...ormation for configuration and status monitoring Be a part of the ongoing improvement of the information contained in this manual Please contact our Technical Support team if you have any suggestions...

Страница 39: ...minated biphenyls PBBs polybrominated diphenyl ethers PBDEs bis 2 ethylhexyl phthalat DEHP benzyl butyl phthalate BBP dibutyl phthalate DBP or diisobutyl phthalate DIBP above the legal limits WEEE sta...

Страница 40: ...al Synchronization Input GND Ground GNSS Global Navigation Satellite System GPS Global Positioning System HP Horizontal Pitch IMS Intelligent Modular Synchronization I O Input Output LTOS LANTIME Oper...

Отзывы: