![Meinberg GPS165 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/meinberg/gps165/gps165_manual_1766202034.webp)
7.2 Power Supply Connector
Connection Type:
5pin DFK
Pinbelegung:
1: N/-
2: not connected
3: PE (Protective Earth)
4: not connected
5: L/+
Input Parameter
——————————————————————————–
Nominal Voltage Range:
U
N
=
100-240 V
∼
100-240 V
Max. Voltage Range:
U
max
=
85-264 V
∼
90-264 V
Nominal Current:
I
N
=
0.15 A
Nominal Frequency Range:
f
N
=
50-60 Hz
Max. Frequency Range:
f
max
=
47-63 Hz
Inrush Current:
I
P
=
50 A @ 230 V AC
Output Parameter
——————————————————————————–
Max. Power:
P
max
=
15 W
Max. Heat Emission:
E
therm
=
54.00 kJ/h (51.19 BTU/h)
N/-
L/+
100-240 V /
100-240 V , 50-60 Hz
5
4
3
2
1
Power
WARNING!
This equipment is operated at a hazardous voltage.
Danger to life due to electrical shock!
- Only qualified personnel (electricians) may connect the device.
- Never work with open terminals and plugs while the power is on.
- All connectors must be protected against touching live parts with
a suitable plug housing!
- Note: Always ensure safe wiring!
- Important: The device must be connected to a proper grounding (PE).