9760465
44 / 56
8.10.1 View parameters
1.Switch to security authorisation level 1
Service level (10000)
, see chapter
“Change authorisation level” on page 42.
2. Choose the entry 1
–1.
3. Confirm the selection.
The first parameter is displayed.
4. Scroll through and view the parameters with the wash programme keys.
The service level can be departed with the
on/off key
.
8.10.2 Ventilating the pipes
The ventilation of the detergent or rinse pipes must be performed if air is sucked in
from the dosing units. This occurs if a canister is completely emptied during opera-
tion, or if one of the suction lances is not threaded through to the base of the canis-
ter.
1. Switch to authorisation level 1
Service level (10001)
, see page 42.
2. Select the entry 1
–3 for ventilating the detergent pipe, and entry 1–2 for the
rinse pipe.
3. Confirm the selection.
The respective pipes are being ventilated, and the remaining time in seconds is
displayed. If necessary, repeat ventilation.
Venting can be cancelled with the
on/off key
.