9756269
12 / 18
8
Notes if TopCut is not working properly
Bags are being used which do not adhere to the specifications. Only use suitable
bags as listed in the section on "Suitable bag types."
Bags are being inserted incorrectly. -> Insert the bags as shown in the section
on"Suitable bag types."
The blade is blunt or damaged and is therefore unable to pierce the film. -> Have
the blade replaced by an authorised member of staff.
The the mechanism is buckled or not running smoothly, an authorised member of
staff will be required to return the TopCut to its operational state or, if appropriate,
replace it.
The retaining plate is not screwed onto the bracket on the TopCut. The TopCut is
pushed upwards when the door is closed. -> An authorised member of staff must
be informed and the TopCut correctly mounted.
The vessel holder is buckled, meaning utensils are not being cleaned properly. ->
An authorised member of staff will be required to return the TopCut to its
operational state or, if appropriate, replace it.
The utensils are not being properly loaded or unsuitable utensils are being loaded
(see section on "Suitable care utensils") and are not being properly cleaned. ->
Care utensils must be loaded as shown in the section on "Suitable care utensils."
Unsuitable care utensils may not be washed in the TopCut.
Содержание TopCut H
Страница 5: ...5 18 9756269 BBraun Ureofix BBraun secretion bag Worek with outlet BBraun Vacufix...
Страница 7: ...7 18 9756269 3 Structure Locking lever TopCut H Blade Bag feed Vessel holder...
Страница 15: ...15 18 9756269 12 Spare parts list Bag cutter TOPCUT H 12 8 9 10 1 6 4 3 12 5 11 12 10 15 15 14 2 13 7...