9625762
36 / 44
16 Trouble-shooting
Despite being expertly designed, the machine may develop minor faults which are usually
easy to eliminate. This section explains a number of possible problems and how you can
deal with them yourself.
Before carrying out work on the open appliance, it MUST be disconnected from the
power supply. The machine is to be switched off completely with the on-site power dis-
connection device here.
Should any of the operational faults described arise repeatedly, their cause must be
established in each case.
Faults not described here can in general only be eliminated by a technician or electri-
cian. Please contact the agency responsible or the authorised dealer.
16.1 Information reporting and troubleshooting
Figure 2: Information display
Information displays can be cleared by pressing the confirmation key.
Provided that the machine function is restored, the next program sequence will begin. The
information display can also be deleted by pressing the “Off” key.
Information indicator (extract)
Info No. Description
Possible cause
120
Emergency program active
Restricted washing possible.
No boiler / tank heating
No fresh water supply
Check system
121
Hood not closed
Check connection S1
Change microswitch
Check microswitch adjustment
Replacing a defective I/O circuit board
122
Incorrect password /
no authorization
Enter code once again
123
Factory setting parameter list
Switch power supply ON/OFF within 5
minutes and set parameters back to
factory settings.
This will be rejected and parameters will
be retained.
Information 123 will disappear
126
Maintenance required
The set operating hours (P122) or batch
number (P123) has been reached. In-
form the service department and per-
form maintenance.
Reset the maintenance counter (P124)
323
Hood propulsion active
Hood drive active; also when the appli-
ance is switched off
324
Opening the hood after a block-
age
Basket under closing hood. Information
remains pending until the button is
pressed again.
Confirmation key
“Off” key