15.5 Assignment list
View inputs / control outputs
Indication
Input / output / other
Conditions
Left
Right
In
1
0/1
Hood closed
none
In
2
0/1
Boiler level
none
In
3
0/1
Leak water switch floor
none
In
4
0/1
not occupied
none
In
5
0/1
not occupied
none
In
6
0/1
not occupied
none
In
7
0/1
Hall-sensor ADT (vacuum dosing)
none
In
8
0/1
not occupied
none
In
9
0/1
Level rinse aid (option)
none
In
10
0/1
Level detergents (optin)
none
In
11
0/1
Leak water switch dosage
none
In
12
0/1
not occupied
none
In
13
0/1
Threshold tank level. 1
none
In
14
0/1
Threshold tank level. 2
none
In
15
0/1
Threshold tank level. 3
none
In
16
0/1
Tank level. 4 (Option)
none
In
17 0 .. 255
Without function
none
In
18 0 .. 255
Without function
none
In
19
xxx
Boiler temperature in °C or °F
none
In
20
xxx
Tank temperature in °C or °F
none
In
21
xxx
Tank level (1 mm unit)
none
In
22 0 .. 255
Without function
none
Ou
1
0/1
Booster Pump
No leak water
Ou
2
0/1
Swivel wash arm
No leak water
Ou
3
0/1
Drain pump
No leak water
Ou
4
0/1
Rinse aid – dosage pump
No leak water
Ou
5
0/1
Detergent – dosage pump
No leak water
Ou
6
0/1
Operation indicator
No leak water
Ou
7
0/1
Filling valve
No leak water
Ou
8
0/1
SASm soft starter system
none
Ou
9
0/1
Boiler heating
No leak water
Ou 10
0/1
Tank heating
No leak water
Ou 11
0/1
Wash pump
No leak water
Ou 12
0/1
Pressure reduction (option)
No leak water
Ou7 4
0/1
Booster pump water softener
No leak water
Ou7 5
0/1
not occupied
none
Ou7 6
0/1
not occupied
none
Ou7 8
0/1
Solenoid valve Y2 EW
No leak water
Ou7 9
0/1
Solenoid valve Y3 EW
No leak water
Ou7 10
0/1
Solenoid valve Y4 EW
No leak water
Ou7 11
0/1
Solenoid valve Y5 EW
No leak water
Ou7 12
0/1
not occupied
none
Leak water switch condition: Leak water switch must not have operated.
Heating condition:
Tank / boiler heating are inter-locked (boiler priority)
Tank heating only when boiler heating deactivated