10
Amber LED Light Codes
If the amber LED flashes, this indicates that a fault has been detected on one of the CF7906 main
modules. These types of faults can be fixed at the machine and can be, for example, caused by; a coin
jam; dirt built up; or if the cassette has been removed. The CF7906 will also indicate the module
affected on its’ display.
Flashes
Check CF7906 Module
1 x
Acceptor jam
2 x
Accept gate alarm
3 x
Separator module,
Cassette out
4 x
Dispenser
( A,B,C,D,E,F ) jam
A
A
A
A
Clearing a Coin Jam
If a coin jams in the dispenser, the Amber light will flash
4
times.
The display will show the average face, a small icon of the changer
with an arrow pointing to the dispenser, the word Alert, and Dispenser
(A- F), (the dispenser that is jammed).
Clear the jammed coin(s) and
press
the letter button of the jammed
tube. This will cycle the dispenser disk and put it in the home position.
See figure #1.