CashFlow
®
540 changegiver Pocket Guide
12
,
MEI., 1997
High-value coins are
rejected and exact change
light is ON
Too few coins in the change tubes,
leaving the low-level sensors
uncovered
Unit is in No overpay mode
. N.B.
Does not apply to MDB applications
Re-float the coin tubes through the acceptor until the low-level
sensor mirrors are covered.
Check Route Alpha 250 address 242.
Incorrect change is
dispensed
Insufficient change coins are
available
Incorrect coin values are set.
Incorrect prices are set for required
selections.
N.B.
Price control is
held in the vending machine in MDB
applications, and are normally held
in the vending machine in Executive
and BDV applications.
If required, float up through acceptor with correct change coins.
Check coin values and prices, reset if necessary using the
Route Alpha 250 terminal. Press A, B, C and D to check if
change coins are dispensed.
Check that coins are being routed to the tubes correctly.
Problem
Causes
Actions