background image

MET1000

All in One True RMS Electrical Tester

User Guide

p

h

one

:

  

800

-

903

-

9870

    

440

-

378

-

6580

     

  f

a

x:

  

800

-

903

-

9590

 

   440

-

238

-

0660

www.w

esc

h

ler

.

com     in

f

o

@w

esc

h

ler

.

com

WESCHLER INSTRUMENTS

Authorized 

Distri

b

utor

:

 

Содержание MET1000

Страница 1: ...MET1000 All in One True RMS Electrical Tester User Guide phone 800 903 9870 440 378 6580 fax 800 903 9590 440 238 0660 www weschler com info weschler com WESCHLER INSTRUMENTS Authorized Distributor...

Страница 2: ...of its products from time to time without notice Although every effort is made to ensure the accuracy of the information contained within this document it is not warranted or represented by Megger Lt...

Страница 3: ...iance with Directive 2014 53 EU Other equipment manufactured by Megger Instruments Limited described in this user guide is in compliance with Directives 2014 30 EU and 2014 35 EU where they apply This...

Страница 4: ...tester if the tester is not operating properly or if it is wet Personal protective equipment must be used if hazardous live parts in the installation where the measurement is to be carried out could b...

Страница 5: ...outside the building and the consumer unit CATIII Measurement category III Equipment connected between the consumer unit and the electrical outlets CATII Measurement category II Equipment connected b...

Страница 6: ...itted or are exhausted the tester is capable of measuring 45 VAC and or 35 VDC Timing Rating tr 30 seconds Recovery Time rt 240 seconds when measuring 300 V recovery time is necessary L R LED may ligh...

Страница 7: ...Continuity Check 7 Voltage Continuity Single Pole Mode...

Страница 8: ...test lead if fitted To carry out Single Pole Check test while firmly holding the MET1000 connect the test lead into a live circuit this will cause the MET1000 to repeatedly beep and the hazard symbol...

Страница 9: ...Counter clockwise Phase Sequence L1 L3 L2 Left Source Grip firmly Terminal G Warning Phase Rotation Test works only on 3 phase 4 wire systems The result is unreliable on any other systems G Note It m...

Страница 10: ...Resistor Mode 10 Resistor Mode...

Страница 11: ...jaw G Do not hold the meter above the barrier Barrier for hand guard G Warning The barrier guard on the meter provides maximum protection when holding the unit in normal use G Warning Remove the test...

Страница 12: ...LD Press Enable Disable ELV Warning Voice Press 5sec Press 5sec Voltage Continuity Single Pole Mode Voltage Continuity Single Pole Mode Press A button and HOLD button at the same time Powering ON OFF...

Страница 13: ...Torch Press 2 sec Powering ON Self diagnostic test or Press OFF G Warning Do not use the tester if a fault is indicated during self diagnostic test 13 Using the Functions...

Страница 14: ...Function Button Resistor Mode Current Mode Voltage Continuity Single Pole Mode Press Button Press Button 2 sec Press Button 14 Using the Functions...

Страница 15: ...t Press here Press here G Warning Replace the batteries as soon as the low battery indicator starts to flash to avoid false readings Remove test leads from meter before opening the battery cover 15 Ba...

Страница 16: ...s G Warning For CAT III or CAT IV environments use the test leads with the probe tip guard cap fixed firmly in place Without the probe tip guard cap the test leads can ONLY be used in a CAT II environ...

Страница 17: ...lead assembly Press here G Warning Do not attach test leads onto the back of the meter while measuring current For 19mm power socket For most applications except current measurement 17 Test lead asse...

Страница 18: ...61010 1 IEC EN 61010 2 032 IEC EN 61010 2 033 IEC EN 61010 031 for CAT IV 600V CATIII 1000V IEC EN 61326 1 IEC EN 61243 3 Environmental Conditions Indoor Outdoor Use Pollution degree 2 Maximum Operat...

Страница 19: ...met for approx 10 seconds The Auto Power On condition is not met Both buttons are not pressed The meter automatically turns off if one of the following conditions are met for approx 30 seconds The re...

Страница 20: ...V AC Voltage Range Resolution Accuracy With batteries 6 0 V 1 to 999 9 V 0 1 V 1 5 5D Without batteries 2 45 V to 999 9 V 0 1 V 1 For 65 Hz the minimum range is 8 0 V 2 Measurement without batteries...

Страница 21: ...tion Accuracy 200 0 A 0 1 A 3 0 5D Frequency Response 45 Hz to 65 Hz Overload Protection AC DC 200 A Rotary Field Indication For 3 phase 4 wire system only Sensitivity 90 V to 1000 V Phase to ground F...

Страница 22: ...nd Electronic equipment The registration No is WEE DJ2235XR Users of Megger products in the UK may dispose of them at the end of their useful life by contacting B2B Compliance at www b2bcompliance org...

Страница 23: ...ion or handling Any implied warranties arising out of the sale of this product including but not limited to implied warranties of merchantability and fitness for a particular purpose are limited to th...

Отзывы: