5.8 Auto test sequence
5.8.1 Description
The autotest function is a great time saver. The user can select which tests they would like to perform and then the
EVCC300 will run through all of the tests one by one automatically
5.8.2 Test selection
1. Switch the instrument ON
2. Use softkeys 1 and 3 to select the “AUTO” test indicated
in white
3. Press softkey 2 to select the test
4. On the Autotest screen use the up and down softkeys (1 and
3) to highlight the test you wish to switch on or off. Tests
switched on (toggle in upper position) will be performed
during the autotest sequence. There are three tests you can
switch on or off. These are:
a. Protective bonding (RPE)
If the charger being tested is double insulated with
no external metalwork this test would not
be required
b. RCD / GFCI
If you are unable to access the RCD or GDCI and
therefore unable to reset it, do not perform this test.
When selecting the RCD / GFCI test the user will
be asked to select which test they wish to perform
during the auto sequence.
c. Reset Charger
Switch on if you wish to reset the charger at the end
of the autotest sequence
5. Use the select key to toggle the tests on or off.
5.8.3 How to perform the test
1. Press and hold the TEST button to start the autotest sequence
2. The EVCC300 will perform each test in the order shown
3. Follow the instructions on the display
34
Tests