6.2.1 For a unidirectional test:
As the test starts, continuity indicators will fade.
Dashes or previous value will flash on the main display until
result appears.
On the secondary display dashes or previous results will flash
until a new result is ready.
The soft keys will not operate during this test.
6.2.2 For a bidirectional test:
As the test starts, continuity indicators will fade.
The left arrow with dashes will flash first until a result appears,
then the right arrow with dashes will flash until
a result appears.
Dashes or previous value will flash on the main display until
average of the two results appears.
On the secondary display dashes or previous results will flash
until a new result is ready.
The soft keys will not operate during this test.
6.2.3 After the test:
For a single test the result is displayed constant in the
main field.
To perform another test press the TEST button (continuity
indicators must be green).
Note:
Soft key 1 toggles continuous / single test.
Soft keys 2 / 3 cycles through current ratings; default is 2
A, selectable 1 A, 100 mA, 10 mA, 1 mA.
Soft key 4 is only active in bidirectional resistance mode
and toggles between ‘Display previous 2 results’ / ‘Forward
and reverse direction’.
TICK button sets new reference value.
For a continuous test results in the secondary screen will keep
updating. Tests will be performed back to back.
‘Two previous results’ in the secondary screen, left is previous
result and right is the result before that.
To stop the test press the TEST button.
If continuity is maintained, pressing the TEST button will
start a new test
Tests, Resistance mode
www.megger.com