DPM1000 

User guide
EN

Содержание DPM1000

Страница 1: ...DPM1000 User guide EN...

Страница 2: ...false readings that can lead to electric shock and injury replace the battery as soon as the low battery indicator blinks Disconnect circuit power and discharge all high voltage capacitors before test...

Страница 3: ...quipment protected by double or reinforced insulation Battery g Earth a AC measurement Bluetooth c Conforms to EU directives Application around and removal from hazardous live conductors is permitted...

Страница 4: ...9 sample values Bluetooth communication Torch turns on when clamp jaws open Auto selecting 1000 A AC DC current measurement Auto selecting 1000 V AC DC voltage measurement 100 k Resistance measurement...

Страница 5: ...packing you should have the following items 1 Megger DPM1000 Power Clamp Meter 2 Test lead set one black one red 3 Test probes one black one red 4 Crocodile clips one black one red 5 TP100 Temperatur...

Страница 6: ...The Meter Description 1 Jaw 2 VoltSeek LED 3 Jaw trigger 4 Rotary function switch 5 LCD display 6 Function Operation push buttons 7 input terminal 8 Common input terminal User Guide www megger com 6...

Страница 7: ...ff The meter can operate again by turning it on from the OFF position After turning on the meter the LCD will show Full hAlf and Lo to indicate the battery capacity After 15 minutes of no activity www...

Страница 8: ...Auto Power Off APO disable Press OK button while turning meter on from the OFF position Push Buttons Menu Operation Bluetooth LEFT UP DOWN RIGHT User Guide www megger com 8...

Страница 9: ...linking cursor to the target icon and then press OK button Use Arrow keys to move the blinking cursor to the target icon and then press OK button for more than 2 sec The icon without an underline mean...

Страница 10: ...Measuring voltage G Warning To avoid an electrical shock hazard or damage to the meter do not attempt a measurement that might exceed 1000 V DC or AC RMS User Guide www megger com 10...

Страница 11: ...rent The torch turns on when the clamp jaws open GCAT IV 600 V CAT III 1000 V with respect to earth for the jaw Fixed Barrier hand guard GDo not hold the meter above the fixed barrier www megger com U...

Страница 12: ...whichever is greater AC mode AC only with RMS value DC mode DC value AC DC mode AC DC RMS value Note Press MODE button to enter the AC DC AC DC mode Press MODE button for more than 2 seconds to retur...

Страница 13: ...LD mode the meter will save the positive peak value and negative peak value Positive peak value is displayed in PEAK MAX mode Negative peak value is displayed in PEAK MIN mode 2SEC 2SEC 2SEC www megge...

Страница 14: ...the measured inrush current could be greater than 100 A AC please set the range to 1000 A prior to activating inrush current After trigger even Motor off Trigger point Motor on Time Waiting for trigge...

Страница 15: ...ey 2 seconds to compensate for any residual magnetism DCA Zero is available in Auto Sense DC and AC DC modes Measuring Frequency AC mode only Select the Hz icon then press the OK button to enter exit...

Страница 16: ...r above the recorded maximum value the meter records the new value The MAX MIN AVG mode can also calculate the average of the readings NOTE Press the HOLD key in Max Min AVG mode to stop the meter upd...

Страница 17: ...monics RMS of fundamental 100 harmonics up to the 25th Hn RMS of Individual Harmonic RMS of fundamental 100 Press RANGE button to display harmonic order or the value of the harmonic unit the value of...

Страница 18: ...t lead to the N and the Red test lead to the L Step 3 Press the trigger to open the transformer jaws and clamp one conductor only making sure that the jaw is firmly closed Step 4 Use the MODE button t...

Страница 19: ...ge signal inductive load _ sign The phase of the current signal is leading the voltage signal capacitive load Overrange display OL U Voltage overload OL A Current overload OL kW Active Power 1050 kW o...

Страница 20: ...ee phase power measurement 3 phase 3 wire balanced unbalanced Step 1 Set the rotary switch to the W position Step 2 Using the MODE button choose ACW Red Red Load Black Black User Guide www megger com...

Страница 21: ...3 phase 4 wire balanced unbalanced Step 1 Set the rotary switch to the W position Step 2 Using the MODE button choose ACW Load Red Red Red Black Black Black www megger com User Guide 21...

Страница 22: ...Phase rotation Phase 1 Phase 2 Phase 3 User Guide www megger com 22...

Страница 23: ...ut 3 seconds Step 4 If it displays L2 then BUZZER will sound twice Please switch the Red test lead to connect to the supposed phase Line 2 immediately before the L2 disappears Step 5 When L2 disappear...

Страница 24: ...power and discharge all high voltage capacitors before measuring resistance and diode Note Press MODE button to enter the or mode Press MODE button for more than 2 seconds to return to the AUTO SENSE...

Страница 25: ...er or to the equipment under test disconnect circuit power and discharge all high voltage capacitors before measuring capacitance Use the DC voltage function to confirm that the capacitor discharged N...

Страница 26: ...et the rotary switch to the position Do not take any high voltage measurement prior to making a temperature measurement as C F measurement accuracy may be affected K Type Temperature probe Vent Pipe U...

Страница 27: ...an the displayed reading for V A W MEM mode When measuring you can save the reading to the memory or load it from the memory The meter can store a maximum of 1000 data entries To enter MEM mode use th...

Страница 28: ...mory Press RANGE button to display the number of records saved current measured value Press OK button for more than 2 seconds to exit the mode LOAD Press OK button to enter exit LOAD mode Press LEFT o...

Страница 29: ...he Megger LinkTM App Turn on the Bluetooth function of the meter by pressing the Bluetooth button and open the Megger LinkTM App to connect the DCM The Bluetooth icon of the meter will flash whilst co...

Страница 30: ...be present Buzzer The meter beeps once for every valid key press and beeps twice for any invalid key press The meter will beep twice on 3 occasions prior to APO Auto Power Off Power up options Press o...

Страница 31: ...ll test leads from Meter before opening the battery cover or meter case Battery state Description Replace the battery as soon as the low battery indicator appears to avoid inaccurate readings The batt...

Страница 32: ...ght approx 600 g with battery Environmental Conditions Indoor Use Calibration One year calibration cycle Operating temperature 0 C 10 C 10 C 30 C 80 RH 30 C 40 C 75 RH 40 C 50 C 45 RH Storage temperat...

Страница 33: ...to the RMS value of a sine wave input Accuracies are given for sine wave at full scale and non sine wave below half scale For non sine wave 50 60 Hz add the following Crest Factor corrections For Cre...

Страница 34: ...ompensate it 3 Peak Hold Peak MAX Peak MIN Accuracy defined for Sine wave ACV 5 Vrms ACA 5 Arms Frequency 50 400 Hz For square wave the accuracy is unspecified Only suitable for the repetitive events...

Страница 35: ...y rdy If the fundamental frequency out of range 45 65 Hz it will display out F 6 Inrush Current Accuracy defined for Sine wave Freq 50 60 Hz Operational response approx 100 ms Trigger level of INRUSH...

Страница 36: ...educted from any resistance measurement taken Max Test Current Approx 0 5 mA Maximum Open Circuit Voltage for Approximate 3 V Maximum Open Circuit Voltage for diode Approximate 1 8 V Continuity Thresh...

Страница 37: ...ance The meter needs 2 hour for stability for any ambient temperature change of more than 5 C 12 VoltSeek Voltage Range of Sensitivity 100 1000 V AC At the top edge of the jaw Product manufactured in...

Страница 38: ...registration No is WEE DJ2235XR Users of Megger products in the UK may dispose of them at the end of their useful life by contacting B2B Compliance at www b2bcompliance org uk or by telephone on 0169...

Страница 39: ...s of operation or handling Any implied warranties arising out of the sale of this product including but not limited to implied warranties of merchantability and fitness for a particular purpose are li...

Страница 40: ...oad Dover Kent CT17 9EN ENGLAND T 44 0 1 304 502101 F 44 0 1 304 207342 Megger GmbH Weststra e 59 52074 Aachen Germany T 49 0 241 91380 500 E info megger de Megger USA Valley Forge Valley Forge Corpor...