Mega Catch Premier MCP800 Скачать руководство пользователя страница 1

Mosquito Trap

Operation Manual

Premier 

Model MCP

800

Pub. No: USA Version P

1006

All manuals and user guides at all-guides.com

all-guides.com

Содержание Premier MCP800

Страница 1: ...Mosquito Trap Operation Manual Premier Model MCP800 Pub No USA Version P1006 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ...s 7 Operation of the Programmable Timer 8 9 Mosquito Catching Systems 10 Using the Liquid Catch Container 10 Using the Catch Bag 11 Fitting of External Skirt 12 13 Care of Your Trap 13 14 Replacement of U V Bulb 14 Mega Catch Octenol Fragrance Strip 15 Optional Accessories 16 Maintenance and Repair of Your Trap 17 19 Removal of Timer 20 Frequently Asked Questions 21 Problem Solving 22 Specificatio...

Страница 3: ...er Cords are placed carefully to avoid causing a tripping hazard Ensure the Trap is properly installed in accordance with this operation manual Read and follow instructions in this operation manual carefully before operating the Trap Your Mega Catch Mosquito Trap should be used in conjunction with other sensible control measures designed to manage mosquito problems Eliminate standing water in low ...

Страница 4: ...culture in Gainesville Florida Mega Catch has developed one of the world s most advanced mosquito traps the Mega Catch PREMIER Mosquito Trap Features of Mega Catch PREMIER Mosquito Trap The Mega Catch PREMIER Mosquito Trap has been designed for indoor or outdoor use NOTE when operating the PREMIER Trap indoors remove the Mega Catch Octenol Fragrance Strip The PREMIER can operate unattended for lon...

Страница 5: ...atch system fill the Liquid Catch Container two thirds full with fresh water Add 2 or 3 drops of liquid detergent soap to break the surface tension of the water Also add 3 or 4 teaspoons of a non diet sugar based soft drink Then place the Liquid Catch Container in the Trap using the locating feet on its base 9 Remove the Mega Catch Octenol Fragrance Strip from its pouch being careful not to touch ...

Страница 6: ...onnectors Plug the extension cord into the Trap connection turning the connector clockwise until tight Plug the extension cord into the transformer cable turning the connector clockwise until tight Then plug into the power supply NOTE The connectors are designed to be a tight fit to ensure that they are weatherproof 13 Turn on the power A display should appear on the face of the Timer If it does n...

Страница 7: ...ending on the type of mosquitoes you are catching Your Mega Catch Mosquito Trap is supplied with a 60 foot 18 meter low voltage extension cord with weatherproof fittings To avoid the cord posing a tripping hazard or being damaged e g by a lawn mower we recommend that if possible it be placed 2 3 inches 50 75 mm underground This can be easily achieved by using a spade which is inserted into the gro...

Страница 8: ... the Trap in a predominantly shaded area Most mosquitoes avoid direct sunlight Rule 5 Place the Trap in a location protected from rain and strong wind Mosquitoes don t fly in strong winds Rule 6 If severe weather conditions are predicted then store the Trap out of the weather For maximum stability point the small U shaped leg at the back of the Stand into the prevailing wind and pin the base to th...

Страница 9: ...inted in the direction of prevailing winds The wire staples supplied with the trap or a cinder block placed on the back of the stand can be used to increase stability Fit top section over bottom section of upright then fit bolt and tighten firmly Assemble stand base components as illustrated here fit all bolts and washers before tightening bolts firmly Screw feet into bottom of stand base 3 x 4 Wi...

Страница 10: ... a power source 2 OFF the Mega Catch Mosquito Trap will not operate 3 AUTO you can program when the Mega Catch Mosquito Trap will start and stop Operation of the Programmable Timer AM 12 3333 Mega Catch Fr R RESET RECALL AM 1 ON _ _ _ _ Mega Catch Mo Tu We Th Fr Sa Su R RESET RECALL FIG 3 1 FIG 3 2 How to Program FIRST SET THE TIME To set the day and time press and hold the CLOCK button while pres...

Страница 11: ...g programmed times OFF system will not operate at all NOTE If the Trap does not operate when the program mode is set to AUTO it may be in stop time program To check switch the program mode to ON which should start the Trap before returning the program mode to AUTO AM 2 ON _ _ _ _ Mega Catch Mo Tu We Th Fr Sa Su R RESET RECALL AM 1 OFF _ _ _ _ Mega Catch Mo Tu We Th Fr Sa Su R RESET RECALL AM 2 OFF...

Страница 12: ...n inside the Trap may cause injury if the power is not disconnected 2 Unlock and remove the Lockable Door 3 Slide the Liquid Catch Container out from beneath the Fan This container has locating feet on its base 4 Fill the container with water until it is approximately two thirds full Add 3 or 4 drops of liquid detergent soap and stir thoroughly This breaks the surface tension of the water ensuring...

Страница 13: ...rational Then pull the drawstring tight so that any mosquitoes that remain alive cannot escape Crush the top of the Catch Bag down on its base to kill any mosquitoes that do remain alive Dispose of the contents well away from your dwelling so as not to attract ants Mosquitoes collected in the Catch Bag will usually die very quickly without access to moisture In cooler climates they may live for a ...

Страница 14: ...ce 2 Slide the Skirt on from the top of the Trap over 2 corners initially with the elastic band at the top 3 The Skirt is properly fitted when the elastic band is seated over the lower horizontal rib just below the inlet holes see figure 5 The opening in the Skirt should be located at the front of the Trap so as to facilitate removal of the Door without having to remove the Skirt The hook and loop...

Страница 15: ...aintenance The Catch Bag and Liquid Catch Container should be cleaned and washed when required Heavy catches of mosquitoes may result in a build up of material in the internal casing and blade tips of the Fan There may also be a build up of material on the Fan Safety Guard If this happens use the following cleaning technique 1 Ensure the power to your Mega Catch Mosquito Trap is disconnected Atten...

Страница 16: ... 17 Maintenance and Repair of Your Trap section To remove safety guard turn counterclockwise until lugs release To fit align 4 lugs on fan housing with 4 slots on safety guard then turn clockwise until tight Lug Lug Lug Lug Slot Slot Slot Slot Rotate clockwise to fit and tighten Rotate counterclockwise to remove Bottom plate FIG 6 Removal of Fan Safety Guard Replacement of U V Blub The U V Bulb is...

Страница 17: ...Reconnect power Wash your hands after this procedure has been completed Mega Catch Octenol Fragrance Strips should be effective for up to 30 days depending on weather conditions Mega Catch Octenol Fragrance Strips are a consumable item and replacements can be obtained from your Authorized Distributor NOTE Octenol can improve the rate of capture of some mosquito species Other species e g the Asian ...

Страница 18: ...he negative battery terminal can result in major damage to your Mega Catch Mosquito Trap and may void your warranty 2 Cigarette Lighter Car Accessory Terminal Cable The Mega Catch Mosquito Trap can be operated from your vehicle s accessory terminal using the factory approved Accessory Cable Your Authorized Distributor can supply a factory approved Accessory Cable NOTE Failure to use only the facto...

Страница 19: ...ening the Trap The two halves of the Trap are held together with 12 stainless steel screws and nuts six facing one way and six the other way Place the Trap on a table ensuring the Programmable Timer is on the side facing down Remove the six screws facing toward you using a hex head screwdriver Then turn the Trap over so that it is timer side up and remove the remaining six screws and nuts Then lif...

Страница 20: ...ot forced it is not possible to plug any connector into the wrong connector hole There are three connector holes on the underside of the Top Plate The two smaller two pin connector holes are for the Fan and Heater Cables These two connections are interchangeable so it doesn t matter which of these two connector holes the Fan and Heater are plugged into The third connection on the underside of the ...

Страница 21: ...t on underside of top plate Power cable plugs into Control Box Timer cable plugs into Control Box U V cable plugs into 3 pin socket on underside of top plate Control Box Heater cable plugs into 2 pin socket on underside of top plate FIG 8 2 Replacement of U V bulb FIG 8 1 Opening the PREMIER Trap All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 22: ...ush the Timer Unit out from the inside of the Trap Removal of Timer Disposal of Timer It is illegal in many states and environmentally undesirable to dispose of the Timer Unit containing the battery in municipal trash A fee has been paid to the Rechargeable Battery Recycling Corporation RBRC to collect these batteries and recycle them rather than incinerate or bury them For information on our batt...

Страница 23: ...t is operated in accordance with the instructions in this operation manual Ensure you read the Important Safety Instructions at the start of this operation manual Do not operate the PREMIER Trap indoors without first removing the Octenol Fragrance Strip 4 How many traps should I buy for around my house This depends on the size of your property Generally we recommend one or two Traps depending on t...

Страница 24: ...nting the Fan blade from turning Refer to Page 13 Care of Your Trap section If these steps fail then email us at info megacatch com or call the Service Centre number shown on the separate Warranty Certificate NOTE Do not attempt to access the internal electronic components of your Mega Catch Mosquito Trap Opening of sealed units will void your warranty Problem Solving Need Help Specifications For ...

Страница 25: ...C PU208 4 Lockable Door MC PU203 5 External Skirt MC PU112 6 Power Connection 7 Control Box MC PU05 8 Top Plate MC PU205 9 Light emitting Diodes 10 Internal Power Plugs 11 UV Tube MC PU2 12 Reflective Surface MC PU211 13 Bottom Plate MC PU206 14 Fan Unit MC PU210 15 Fan Safety Guard MC PU209 16 Catch Bag MC PU111 17 Liquid Catch Container MC PU204 18 Octenol Fragrance Strip MC PU224 19 60ft Extens...

Страница 26: ...mited 16th Floor 120 Albert Street Auckland New Zealand info megacatch com www megacatch com Pub No USA P1006 Printed in China Mega Catch is a trademark of Envirosafe Technologies NZ Ltd All manuals and user guides at all guides com a l l g u i d e s c o m ...

Отзывы: