background image

  

Model  954v2  

Operating 

Manual

 Ionising Airgun

Содержание 954v2

Страница 1: ...Model 954v2 Operating Manual Ionising Airgun...

Страница 2: ......

Страница 3: ...please refer to our Head Office or visit www meech com Meech Static Eliminators Ltd 26 10 17 Contents Introduction 3 Unpacking and Inspection 4 General Notes On Operation 4 Installation 5 Compressed A...

Страница 4: ......

Страница 5: ...neutralising static charges and removing dust and contamination on a wide range of industrial processes The 954v2 has many improvements over its predecessors due to innovations in engineering These i...

Страница 6: ...NATORS THIS DOCUMENT AND THE INFORMATION THEREIN IS THE PROPERTY OF THE MEECH GROUP AND SHOULD NOT BE COPIED IN WHOLE OR PART OR USED FOR MANUFACTURE OR OTHERWISE DISCLOSED WITHOUT THE PRIOR WRITTEN C...

Страница 7: ...mance However depending on the application higher or lower pressures may be required Air Connection to the 954v2 is via a standard 6mm push fit fitting Electrical connection Electrical connection is t...

Страница 8: ...mended pressure 3 4 Bar 50PSI Operating voltage 7kV from Meech 904 power unit Max Temperature 85 C Construction Gun handles cast aluminium Nozzle body Nylon Weight 300 g approx Cable 3 metres of H T c...

Страница 9: ...performance Typically weekly inspection cleaning is sufficient The emitter and the inside of the nozzles can usually be cleaned using a cotton bud If the emitter has become very dirty it may need to b...

Страница 10: ...r of the nozzle can be wiped down with a damp cloth Should you have any additional questions regarding the maintenance of Meech equipment please contact Meech International directly or your local Meec...

Страница 11: ...ment make no contact with water or water based fluids Should such an event occur disconnect immediately and return equipment to the manufacture for water damage assessment The 954v2 ionising air gun f...

Страница 12: ...illuminated and the nozzle is clean the system will be working effectively If the green neon indicator is not illuminated consult the operating manual for the 904 for further troubleshooting informati...

Страница 13: ...n a sturdy carton with shock absorbing material Include a note stating the nature of the problem as specifically as possible and also include instructions for returning the bar to you We will pay one...

Страница 14: ......

Страница 15: ......

Страница 16: ...232 4210 Fax 1 330 564 2005 email info meech com Meech Shavotech 29 2 Kharadi Off Pune Nagar Road On Old Kharadi Mundhwa Road Pune 411014 Maharashtra India Tel 91 0 703 093 8211 91 0 741 000 4817 Fax...

Отзывы: