Model 905 

Operating 

Manual

High Voltage Power Supply

Содержание 905 Series

Страница 1: ...Model 905 Operating Manual High Voltage Power Supply...

Страница 2: ......

Страница 3: ...her information please refer to our Head Office or visit www meech com Meech Static Eliminators Ltd 26 10 2017 Contents Introduction 3 Input Voltage and Connection 4 Installation 5 Ionising Equipment...

Страница 4: ......

Страница 5: ...a high voltage output 5 0 kV AC suitable for connection to Meech ionising appliances The Model 905 s unique design features a modified AC output waveform which ensures that ionising appliances attache...

Страница 6: ...reasons this equipment must be grounded earthed either via the mains plug or by direct connection to ground earth 4 High voltage output ON indicator Fused mains IEC input socket Ionising appliance con...

Страница 7: ...pply Failure of the unit through contamination will invalidate the warranty The Model 905 can operate from either a 110V or 240V switchable AC mains supply It is available in two versions 905 50 for 5...

Страница 8: ...lid of the 905 by unscrewing the three retaining screws select the required number of ports one per ionising appliance and remove the necessary grommets from the ports Connect the item of ionising equ...

Страница 9: ...n refit both the lock washer and nut to the appliance connector Ensure that the nut is fully tightened Connect the cable eyelet of the appliance to the high voltage stud of the 905 using the screw pro...

Страница 10: ...Insert the IEC plug into the IEC socket of the 905 ensuring the illuminated ON OFF rocker switch is in the OFF position Connect the free end of the mains cable to the mains supply For safety reasons...

Страница 11: ...9 In normal operation the ON OFF switch will be illuminated red and the High Voltage indicator will be illuminated green...

Страница 12: ...ency 50Hz 60Hz Output 5 0kV 5 0kV Short circuit current 5 mA 5 mA Weight 3 4Kg 3 4Kg High voltage indicator YES YES Fuse 500mA 400mA fast Blow fast Blow Dimensions h x w x d 113x150x130mm 113x150x130m...

Страница 13: ...ce or your local distributor FAULT High Voltage indicator dim or extinguished 1 Check ON OFF switch is illuminated 2 Check voltage selector switch is set to the correct setting 110v 240 V 3 Check main...

Страница 14: ...h on the unit Check to see if the High Voltage indicator is illuminated If illuminated the power supply is OK check ionising appliances attached see appliance Operation and Maintenance Manual Be extre...

Страница 15: ...3 mm If no spark is present then the unit is faulty 6 Check ionising appliance integrity see also the appropriate operation and maintenance manual Attach each ionising appliance individually to the 9...

Страница 16: ...minators Ltd to the original purchaser against defects in material and workmanship for one year after purchase Should any malfunction occur please return the power supply directly to Meech Static Elim...

Страница 17: ...er the warranty Field repairs should not be undertaken during the warranty period Repair attempts by unqualified personnel will invalidate the warranty CE Approval An EC Declaration of Conformity for...

Страница 18: ...16...

Страница 19: ......

Страница 20: ...232 4210 Fax 1 330 564 2005 email info meech com Meech Shavotech 29 2 Kharadi Off Pune Nagar Road On Old Kharadi Mundhwa Road Pune 411014 Maharashtra India Tel 91 0 703 093 8211 91 0 741 000 4817 Fax...