MedSpace DFU-0133 Скачать руководство пользователя страница 1

DISPLAY FRAME UNIT

TM

USER MANUAL

EN

subject to modification, errors and omissions excepted * 11-2014 * V1

Содержание DFU-0133

Страница 1: ...DISPLAY FRAME UNIT TM USER MANUAL EN subject to modification errors and omissions excepted 11 2014 V1...

Страница 2: ...2 we organise your space...

Страница 3: ...rganise your space DISPLAY FRAME UNITTM SUMMARY GENERAL INFORMATION 04 INSTALLATION IN WET ROOMS 12 PRODUCT INFORMATION 13 GETTING STARTED 15 TROUBLESHOOTING 26 TECHNICAL SPECIFICATION 27 WARRANTY TER...

Страница 4: ...not allow the product to come into contact with liquids Liquid in the casing can cause a fire electric shock or damage the device Immediately pull the mains plug out if an item or liquid gets into the...

Страница 5: ...n of the Display Frame UnitTM because it could otherwise be damaged or break Never touch the screen with pointed or sharp items such as pencils ballpoint pens knives scalpels screwdrivers etc Wear pro...

Страница 6: ...ve access to the USB port after installation we recommend installing a USB extension cable CAUTION MedSpace does not offer any guarantee for the screws and dowels delivered with the product These may...

Страница 7: ...d by MedSpace Install the product in a way that it is fixed properly and take care that children are not exposed to danger Please take extra care during installation avoid impacts Before cabling your...

Страница 8: ...while using Do not cover or wrap the adapter Leave space around the adapter to prevent overheating The individual components can be destroyed if the polarity is reversed or an incorrect connection is...

Страница 9: ...er adapter on top or on the back of the monitor system in order to prevent thermal overload Ensure that your installation complies with your national safety rules Any servicing adjustment maintenance...

Страница 10: ...the department of energy and environmental protection agency The ENERGY STAR program exists to provide energy saving guidelines and help promote energy efficient products and practices On delivery con...

Страница 11: ...l resources and will help to prevent potential negative effects on the environment and human health which could otherwise be caused by inappropriate waste handling of these products For more informati...

Страница 12: ...long as the monitor system is shielded from a sealed glass surface and the external power adapter is installed beyond these protection zones NOTE The safety current source has to be arranged outside...

Страница 13: ...tents of the box for completeness Display Frame UnitTM monitor system IR remote control A WATERPROOF for DFU 0133 up to DFU 0216 B SLIMLINE for DFU 0260 up to DFU 0840 Low voltage power adapter A DC 1...

Страница 14: ...t 3 x HDMI terminal 4 RS232 1 x D SUB 9pin male terminal 5 Component input YPbPr 3 x RCA terminal green Y blue Pb red Pr 6 Line audio input 2 x RCA terminal white L red R 7 Speaker output 1 x Phoenix...

Страница 15: ...cables Observe the polarity and of the connections to avoid phase errors incorrect stereo playback External USB media source Connect an external USB media source to the USB 2 socket to display photos...

Страница 16: ...ions Open close OSD menu of DFU Switch between TV and radio Favorite list Sleeptimer Aspect ratio Select audio mode audio track Select program directly Electronic program guide Teletext Videotext Powe...

Страница 17: ...g the IR command has been captured 4 To save this IR code press and release again the key you wish to program on the learning remote The LED indica tor blinks fast and then lights constantly to indica...

Страница 18: ...e values OK confirm selection Open close OSD menu of STB EXIT Switch between TV and radio Favorite list GOTO Previous channel Submenu function buttons Volume up down Channel info Operation guide Mute...

Страница 19: ...st Press the or keys until the desired input source is highlighted Press the key to confirm selection of the chosen input and to clear the input source list from the screen Press the key to close the...

Страница 20: ...ay not be entered directly with the number keys on your remote control Please proceed as follows Press the key once for a 1 twice for a 2 etc Press the key to confirm jump to the next digit Audio Sett...

Страница 21: ...n choose from Off Low Medium High Display Settings Press the key to open the OSD menu Navigate to Display Settings with the or keys Sleep Timer determine a timespan after that the DFU should turn off...

Страница 22: ...r pro tection that limits a quick increase in volume to be passed on to the speaker output port in order to prevent damages to the speakers OSD Settings Press the key to open the OSD menu Navigate to...

Страница 23: ...firmware version via a connected USB media source CAUTION Please make sure that the software file on the USB media source is the correct version for your DFU Please notice that every screen size has a...

Страница 24: ...eters 0 up to 254 The preset IR address code is 0 Input Scan de activate the automatically scan of the input ports for input sources If there is no signal at the currently selected port the DFU search...

Страница 25: ...patible devices and de activate the auto standby function RS 232 Access de activate the RS 232 functionality With RS 232 commands the DFU can be integrated to interactive multimedia solutions like hom...

Страница 26: ...Check that the signal cable connector is properly connected and that the connection pins are not bent or damaged Image is unsatisfactory Adjust the picture characteristics as described in the above me...

Страница 27: ...48 393 0mm 15 47 402 0mm 15 83 735 5mm 28 96 482 5mm 19 00 14 0mm 0 55 35 0mm 1 38 120 0mm 4 72 378 0mm 14 88 29 0mm 1 14 42 0 1035 0mm 40 75 628 0mm 24 72 51 0mm 2 01 52 5mm 2 07 52 5mm 2 07 930 0mm...

Страница 28: ...Total 80 Left 40 Right 40 Vertical Typical Total 45 Up 15 Down 30 Horizontal Typical Total 170 Left 85 Right 85 Vertical Typical Total 160 Up 80 Down 80 Brightness 300cd m2 250cd m2 Contrast Typical...

Страница 29: ...Total 160 Up 80 Down 80 Horizontal Typical Total 176 Left 78 Right 78 Vertical Typical Total 176 Up 78 Down 78 Horizontal Typical Total 178 Left 89 Right 89 Vertical Typical Total 178 Up 89 Down 89 25...

Страница 30: ...176 Left 88 Right 88 Vertical Typical Total 176 Up 88 Down 88 Horizontal Typical Total 176 Left 88 Right 88 Vertical Typical Total 176 Up 88 Down 88 Brightness 450cd m2 460cd m2 Contrast Typical 4000...

Страница 31: ...178 Up 89 Down 89 Horizontal Typical Total 178 Left 89 Right 89 Vertical Typical Total 178 Up 89 Down 89 Horizontal Typical Total 178 Left 89 Right 89 Vertical Typical Total 178 Up 89 Down 89 400cd m...

Страница 32: ...ut 3 x HDMI terminal USB 1 x USB terminal RS232 1 x D SUB 9pin male IR Input Infrared 1 x mini jack 3 5mm Output Ports Speaker Output 1 x Phoenix clip 4pin IR Output cable 1 x mini jack 3 5mm IR Outpu...

Страница 33: ...N DFU SPECIAL FEATURES Special Features DFU 0133 up to DFU 0840 Multimedia Player USB Software Update USB CI Common Interface No Autostart Yes Signal Scan Yes Hotel Mode Yes RS 232 Yes FM Radio No PIP...

Страница 34: ...DIA SUPPORT USB Media Support File Extension Video Audio Movie avi DivX XviD MPEG 4 MP3 WMA AAC mpg MPEG 1 MPEG 2 dat MPEG 1 mov mkv H 264 Music mp3 MP3 wma WMA m4a aac AAC Photo jpg jpeg Progressive...

Страница 35: ...or and a 10uf E L capacitor to output for Ripple Noise measurement 20MHz BW 3 Line regulation measured from 100Vac to 240Vac full load 4 Load regulation is measured from 60 to full load and from 60 to...

Страница 36: ...e LCD LED panel inside the product is broken m Allowable Measurement Treatment and Coating tolerances of the product s glass or mirror as defined in the product specification n Returned products which...

Страница 37: ..._____________________________________________________________________________ Address ___________________________________________________________________________________________________________ Dealer...

Страница 38: ......

Страница 39: ...l How to proceed Prior to sending any goods please make sure to request an RMA Nr from us by phone or email Please complete the RMA form in particular giving as detailed a description as possible of t...

Страница 40: ......

Страница 41: ...ns without indicated valid RMA number cannot be processed and will be refused MedSpace Service and Support Phone 49 7462 923 90 900 Fax 49 7731 923 90 99 E Mail info med space de MedPlan Engineering G...

Страница 42: ......

Страница 43: ......

Страница 44: ...timedia interface are trademarks of HDMI Licensing LLC This product parts components and the assembly are protected by or might be part of one or more of the following intellectual property rights US...