background image

 

 
 

Introduction. 

 

„Dualflow Plus‟ family of hand dryers offers the technical features as follows. 

 

 

Automatic operation. Drying cycle starts when putting hands in. Two couple of IR 

sensors detect hands introduction. 

 

 

Dryer is a class I (earthed) electrical insulation device. 

 

 

Drying process is based on powerful air curtains which remove water from hands. 

 

 

Hand dryer has no heating element. 

 

 

Speed of air can be adjusted in order to achieve an optimum balance between drying 

power and noise level. 

 

 

Light leds on top supply some information referred to the status of hand dryer. 

 

 

Maximum time of continuous operation is T max = 30 sec. 

 

 

Water from hands is collected in an internal tank which may be emptied. 

 

 
Installation. 
 

 

ONLY A QUALIFIED TECHNICIAN CAN INSTALL, ADJUST AND MAINTAIN THIS HAND 

DRYER. 

 

The installation of the appliance is only allowed on fixed wiring. 
 
Means for disconnection of the mains with contact separations at least 3 mm (0.12”) must be 
incorporated in the fixing wiring. 
 
The installer must make sure that the electric system is grounded in accordance with the law in 
force. 
 
Make sure that the electric system has a high-sensitivity breaker I n 

≤ 0.03 A. 

 
Make sure that the machine is disconnected from the electric power supply, before performing 
maintenance operation. 
 
To install the hand dryer follow the pictures contained in the figure 2. 
 
The hand dryer must be fitted to the wall by using the upper metal plate (support) which is 
supplied. 
 
After fitting the metal plate, the hand dryer should be hung on it. The lower screw fits safely the 
appliance to the wall. So, to assemble the hand dryer the following steps must be done. 

 

 

Make three 8 mm (0

.31”) diameter drill holes in the wall using the provided template (1). 

 

 

Clean the dust away and insert the wall plugs. 

INSTALLATION AND MAINTENANCE BOOK (TECHNICAL STAFF) 
 

 

Содержание M12A

Страница 1: ...HAND DRYERS M12A M12ACS INSTALLATION AND OPERATING MANUAL ...

Страница 2: ...de Hand dryer starts automatically after introducing hands Move hands vertically as shown in Fig 1 in order to dry them completely Green light in standby state led on top becomes to orange colour when dryer is in use Maximum continuous operation time is T 30 sec Drying time is less to it Td 8 12 sec After removing hands dryer turns off automatically This appliance can be used by children aged from...

Страница 3: ...e appliance is only allowed on fixed wiring Means for disconnection of the mains with contact separations at least 3 mm 0 12 must be incorporated in the fixing wiring The installer must make sure that the electric system is grounded in accordance with the law in force Make sure that the electric system has a high sensitivity breaker I n 0 03 A Make sure that the machine is disconnected from the el...

Страница 4: ... plastic base3 plate 5 Connect the electrical wires to the hand dryer terminal block Two phases N L and earth wires must be screwed in the right ways of the terminal block as indicated by the engraved letters 6 After this operation has been done plastic covers must be placed correctly 10 Remove the air inlet filter casing 7 Firmly place the lower screw for fixing the appliance completely 8 Put the...

Страница 5: ...ATTENTION WHEN THE CASING IS DISMANTELED ACTIVE PARTS OF THE DEVICE BECOME ACCESSIBLE Installation height must be the showed in figure nº 3 Figure nº 3 ...

Страница 6: ...picture 4 shows Pilot light information Light leds on the top of the hand dryer see figure 5 give advice about 1 Standby green colour or operation status orange colour 2 Red colour led brigths when motor has a problem of consumption due to brushes which may be wearing out or due to a blocked or locked sate of motor 3 Blue colour led brigths when cabinet of water is full Figure nº 4 Figure nº 5 ...

Страница 7: ...ell charge Water tank Water from hands drops directly to an internal water tank When water reaches the full level an acoustic alarm sounds and the blue pilot light bright see Fig 5 In this case water in the tank must be emptied To evacuate the water from tank press the push button as indicated in Fig 8 Figure nº 6 Figure nº 7 Figure nº 8 ...

Страница 8: ...nstaller must make sure that the electric system is grounded in accordance with the law in force Make sure that the electric system has a high sensitivity breaker I n 0 03 A Make sure the machine is disconnected from electric power supply before performing maintenance operation ...

Страница 9: ...COMPONENT NUMBER CODE Motor set 1 RC9111003SMD Electronic control 2 RC9121012SMD Air filter set 3 RCFILTRODFW BASIC EXPLODED VIEW ...

Страница 10: ...tencia Rating Puissance Leistung 1 100 W 1 5 Hp Tipo Type Type Typ Universal de escobillas Universal brush motor Universel à balais Universalmotor Bürsten Velocidad Speed Vitesse Geschwindigkeit 18 000 30 000 rpm TURBINA TURBINE TURBINE TURBINE Centrífuga de alta presión High pressure centrifuge Centrifuge haute pression Hochdruckschleuder DIMENSIONES SIZE DIMENSIONS ABMESSUNGEN Alto Height Hauteu...

Страница 11: ...sorgt werden muss dann liegt es in der Verantwortung des Anwenders das Produkt in einem speziell für elektrische und elektronische Abfallprodukte ausgewiesenen Wertstoffhof zu entsorgen Wenn Sie mehr Information über die Entsorgung von elektrischen und elektronischen Abfallprodukten nach deren Nutzungsdauer wünschen dann setzen Sie sich bitte mit den örtlichen Behörden mit dem für die Hausmüllents...

Отзывы: