Mediclass WAP-900A Скачать руководство пользователя страница 1

 

 

 

Arm Automatic Blood Pressure Meter 

(Electronic Sphygmomanometer) 

User Manual 

Ø

 

Thank you for purchasing our product.   

Ø

 

Please read this manual carefully before using the product.   

Ø

 

Please keep the manual appropriately for future reference.   

Ø

 

This User Manual is for the model WAP-900A 

 

 

 
 
 
 

Содержание WAP-900A

Страница 1: ...tronic Sphygmomanometer User Manual Ø Thank you for purchasing our product Ø Please read this manual carefully before using the product Ø Please keep the manual appropriately for future reference Ø This User Manual is for the model WAP 900A ...

Страница 2: ...Table of Contents I General Information 1 II PRECAUTION FOR USE AND MAINTENANCE 5 III Name of Each Part 8 Note for LCD display 10 IV Measure Procedure 11 V Troubleshooting 22 ...

Страница 3: ...e manual Indications For Use WAP 900A Arm Automatic Blood Pressure Meter is for use by medical professionals or at home and is a non invasive blood pressure measurement system intended to measure the diastolic and systolic blood pressures and pulse rate of an adult individual by using a non invasive technique in which an inflatable cuff is wrapped around the arm The cuff circumference is limited t...

Страница 4: ...ange Pressure 40 280mmHg Pulse 30 160 times minute Accuracy Pressure 5mmHg Pulse 5 Power Supply 6V DC 4 AA batteries Battery Life Approx 250times 180mmHg 1 time day 22 C 71 6 F Working Environment Temperature 5 40 C 41 F 104 F Humidity 85 RH Storage Environment Temperature 20 60 C 4 140 F Humidity 95 RH Environmental Pressure Atmosphere pressure Electric Shock Internal power unit ...

Страница 5: ...deflation system controlled by internal electromagnetic valve Display Pressure Pulse Date Time Switch 3 ON OFF Memory SET Size 135mm 5 3inch L 96mm 3 7inch W 56mm 2 2inch H Weight 241g 0 5 LB Contraindications 1 Heart disease 2 High blood pressure or other circulatory disease 3 Arm injury n Patient Populations The device is intended to use for adults DO NOT use this device on infants ...

Страница 6: ...ubbing as this will cause air leakages Take care also not to get water into the air hose Nature and Frequency of Maintenance This product is designed for use over an extended period of time however it is generally recommended that it be inspected every two years to ensure proper function and performance Protect the Nature Environment Please help to protect natural environment by respecting nationa...

Страница 7: ... ON OFF switch and then consult the sales outlet where you purchased the device 3 If you think the measurement is abnormal or if measurement makes you feel unwell discontinue use and consult your physician 4 Blood pressure measurement may not be possible for anyone with a weak pulse or arrhythmia 5 Repeated blood pressure measurement may cause problems such as congestion or swelling in some people...

Страница 8: ...round an elbow 10 DO NOT wrap the arm cuff around an elbow in which a drip intravenous infusion is inserted or which is being used for blood transfusion as part of medical treatment Doing so could result in an injury or a serious accident 11 DO NOT use the device in the vicinity of flammable gases such as those used for anaesthesia Doing so could ignite the gases and cause an explosion 12 DO NOT u...

Страница 9: ...entricular premature beats or a trial fibrillation 18 This product contains natural rubber latex which may cause allergic reactions Precautions for Maintenance 1 DO NOT store the blood pressure monitor in locations exposed to direct sunlight high temperatures over 60 C 140 F low temperatures below 20 C 4 F high relative humidity over 95 or excessive amounts of dust 2 DO NOT drop the blood pressure...

Страница 10: ...vice 5 DO NOT bend the cuff or air hose excessively 6 NEVER clean the blood pressure meter with thinners or benzene as they may damage it 7 DO NOT hard rub when clean the cuff Take care not to get water into the air hose III Name of Each Part ...

Страница 11: ...9 Figure 1 Appearance v SET Button Clock Setting v MEMORY Button AUg Measured Result recall Clock Number Adjusting v ON OFF Button v LCD v Systolic v Diastolic v Pulse Figure 2 Display of LCD ...

Страница 12: ...Systolic Blood Pressure unit mmHg 4 Diastolic Blood Pressure unit mmHg 5 Pulse unit beat minute 6 WHO BP Classification Indicating Bar 7 Inflation Deflation Indicator 8 Blood Pressure Unit 9 Low Battery 10 Heart Icon Twinkle when measuring 11 Memory Record Number ...

Страница 13: ... polarity Close the battery cover See Figure 3 Note When LCD shows Low Battery icon it means you must change the batteries at once See Figure 4 Rechargeable batteries with a voltage of 5 2V are not suitable for this product Take out all the batteries if the device will be not used for a long time to avoid battery leakage and relevant damage ...

Страница 14: ... of month date hour and minute will twinkle in sequence While the number is twinkling press button MEMORY and the corresponding number will increase by one Hold on pressing the button MEMORY the number will increase fast After pressing SET button the fifth time numbers on LCD will not twinkle then you exit the time adjusting mode See Figure 5 After you change the batteries you have to readjust the...

Страница 15: ...then you can select mmHg or Kpa in turn by repeatedly pressing memory button Arm Cuff Connecting Be sure to place the arm cuff on bare skin or thin skinned cloth on left arm and place the cuff on the center of elbow then warp the arm cuff to keep a distance of 2 3 cm with the elbow See Figure 6 Note Arm cuff connecting should make arm feel no much tension Don t connect too tense otherwise the meas...

Страница 16: ...sition on the same height of heart When the cuff is dirty detach it from the equipment wash the cuff by hand with proper detergent and rinse it in the enough cold water dry in air Never iron it Figure 6 Measuring Process ...

Страница 17: ... After about two seconds LCD shows one 00 See Figure 8 If the device has voice function it will speak out the prompt that keep silence to take cuff at the same height with your heart Then the device begins to pressurize automatically After measurement the result of systolic diastolic and pulse rate will be all displayed on LCD The result will be ...

Страница 18: ...device will be turned off The device will be automatically power off after 1 minute of none use Figure 8 Figure 9 n Assessing High Blood Pressure for Adults The follow standards for assessing high blood pressure without regard to age or gender have been established as a guide line according to WHO World Health Organization standard See Figure 10 Please note that other risk factors ...

Страница 19: ...d may affect these figures Consult with your physician for accurate assessment Figure 10 From the above figure we can see the classification of blood pressure for adults is as below The WHO BP Classification Indicating Bar would show out the blood pressure level by the length ...

Страница 20: ...3 Hypertension 180 110 6 grids Note The graph is not exact but may be used as a guide in understanding non invasive blood pressure measurements The device is only intended for use with adults Reading An Average Of The 3 Most Recent Measurements Result AUg Under OFF condition press the button of MEMORY to enter the mode of an average of the most 3 recent measurements reading result In this conditio...

Страница 21: ...ill be displayed which is 01 for memory number See Figure 11 Continuously press the MEMORY button the memory number will increase by one If the device has voice function it will speak out the last time displayed memory blood pressure and heart rate Press MEMORY button again after the last memory the device will power off Under the memory displaying mode it will be automatically power off after ten...

Страница 22: ... Figure 11 Delete for all Memories Under the mode of reading memories holding on pressing MEMORY button for three seconds all memories will be deleted LCD will show the Figure 12 for two seconds Figure 12 ...

Страница 23: ...ld select P1 prior to turning on the device Similarly prior to checking your memory values you should also select P1 to see your own memory values Voice Function The device with voice function can speak out in the following state Ø The device will speak out the prompt that keep silence to take a cuff at the same height with your heart when the measure begin The device will speak out the displayed ...

Страница 24: ...ws abnormal result Cuff is not tightened properly or its position is incorrect Tighten cuff correctly and refer to Arm Cuff Connecting The arm is moved during measuring Stay calm arm remains steady Do not move during measuring Irregular heartbeat You can test again for light irregular heartbeat patients It is inappropriate for serious irregular heartbeat patients to use this device ...

Страница 25: ...athing Some interference in inflation or wrong operation during measuring Refer to the inflation step in Measuring process LCDshows ErU Insufficient inflation Measure again LCDshows ErH Inflation over 305 mmHg Measure again LCDshows Er1 Undetectable the pulse Measure again LCD shows Er 2 Radiation interference Away the radiation source LCD shows Er 3 Measured result wrong Measure again ...

Отзывы: