Appendix C - Standard Hardware Information
DTMF Tone Detection
40
Mediatrix 4100 – Analog Access Device
DTMF Tone Detection
DTMF Tone Generation
Power Consumption
MTBF Value
The Mean Time Before Failure (MTBF) value of the Mediatrix 4100 models is estimated as follows:
Mediatrix 4108: 200,000 hours
Mediatrix 4116: 190,000 hours
Mediatrix 4124: 180,000 hours
These values are at 25 degrees Celsius ambient temperature. It has been defined using RelCalc v5.0, Bellcore
method (LimitedStress - Method I, Case 3), Desktop unit .
Table 21:
DTMF Tone Detection
Parameter
Description
16-Digit DTMF Decoding
0 to 9, *, #, A, B, C, D
Permitted Amplitude Tilt
High frequency can be +2 dB to -8 dB relative to low frequency
Dynamic Range
-25 dBm to 0 dBm per tone
Frequency Accept
± 1.5% of nominal frequencies
Minimum Tone Duration
40 ms
Interdigit Timing
Detects like digits with a 40 ms interdigit delay
Table 22:
DTMF Tone Generation
Parameter
Description
Per Frequency Nominal
-8 dBm to -5 dBm
Frequency Deviation
Within 1.5% of nominal values
Table 23:
Power Consumption
Parameter
Description
Idle Mode: 120Vac
0.54A 43W
Idle Mode: 240Vac
0.36A 43W
24 Extensions Off-Hook (worst
case): 120Vac
0.58A 66W
24 Extensions Off-Hook (worst
case): 240Vac
0.5A 66W
Содержание Mediatrix 4116
Страница 6: ...Contents vi Mediatrix 4100 Analog Access Device...
Страница 22: ...Chapter 2 Installation Hardware Installation 12 Mediatrix 4100 Analog Access Device...
Страница 30: ...Chapter 3 Powering on the Mediatrix 4100 Management Choices 20 Mediatrix 4100 Analog Access Device...
Страница 46: ...Appendix B Cabling Considerations Loop Current vs Cable Length 36 Mediatrix 4100 Analog Access Device...
Страница 52: ...Appendix C Standard Hardware Information Warranty 42 Mediatrix 4100 Analog Access Device...
Страница 56: ...Appendix D Glossary Wide Area Network WAN 46 Mediatrix 4100 Analog Access Device...
Страница 58: ...Appendix E List of Acronyms 48 Mediatrix 4100 Analog Access Device...