Appendix A - Standards Compliance and Safety Information
Safety Warnings
26
Mediatrix 4100 – Analog Access Device
Safety Warnings
This section lists the following safety warnings:
Circuit Breaker (15A) Warning
TN Power Warning
Product Disposal Warning
No. 26 AWG Warning
LAN and FXS Ports Connectors Warning
Socket Outlet Warning
Circuit Breaker (15A) Warning
TN Power Warning
Product Disposal Warning
No. 26 AWG Warning
LAN anf FXS Ports Connectors Warning
Socket Outlet Warning
Warning:
This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure
that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10A international) is used on the
phase conductors (all current-carrying conductors).
Warning:
The device is designed to work with TN power systems.
Warning:
Ultimate disposal of this product should be handled according to all national laws and
regulations.
Warning:
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
Warning:
Do not connect the LAN and the FXS ports connectors directly to the Public Switched Telephone
Network (PSTN), to an off premise application, an out of plant application, any exposed plant application, or
to any equipment other than the intended application, connection may result in a safety hazard, and/or
defective operation and/or equipment damage.
Exposed plant means where any portion of the circuit is subject to accidental contact with electric lighting or
power conductors operating at a voltage exceeding 300V between conductors or is subject to lightning
strikes.
Warning:
The socket outlet, if used, shall be located near the equipment and shall be easily accessible by
the user.The AC adaptor inlet is considered as disconnection device. The device must be readily
operational.
Содержание Mediatrix 4116
Страница 6: ...Contents vi Mediatrix 4100 Analog Access Device...
Страница 22: ...Chapter 2 Installation Hardware Installation 12 Mediatrix 4100 Analog Access Device...
Страница 30: ...Chapter 3 Powering on the Mediatrix 4100 Management Choices 20 Mediatrix 4100 Analog Access Device...
Страница 46: ...Appendix B Cabling Considerations Loop Current vs Cable Length 36 Mediatrix 4100 Analog Access Device...
Страница 52: ...Appendix C Standard Hardware Information Warranty 42 Mediatrix 4100 Analog Access Device...
Страница 56: ...Appendix D Glossary Wide Area Network WAN 46 Mediatrix 4100 Analog Access Device...
Страница 58: ...Appendix E List of Acronyms 48 Mediatrix 4100 Analog Access Device...