1.
a.
b.
c.
2.
3.
4.
If your computer is connected to the Ethernet port, commonly used to be connected to the Local Area Network (LAN), i.e. ETH2
on most devices, use the 192.168.0.10 IP address
If your Mediatrix unit is configured to use a DHCP server with IPv4, use the provided DHCP server IP address.
Enter
as your username and leave the password field empty.
public
Note: The
username account has administrator rights.
public
Note: You can also use
as a username and
as password.
admin
administrator
Click
.
Login
Contact the Mediatrix unit with an SNMP browser, or
Contact the Mediatrix unit via the CLI, or
Ping the Mediatrix unit.
Top
Cables
Gigabit Ethernet Connection (RJ-45)
Caution: Always use standard telecommunication cables with a minimum of 26 AWG wire gauge.
Gigabit Ethernet requires all four pairs to be present.
Category 5 cables can be used for 10/100 Base T-Connections.
Category 5e or 6 cables are recommended for Gigabyte Ethernet.
It is possible to use either a crossover or a straight Ethernet cable as the Mediatrix units perform automatic MDI/ MDIX detection, meaning that
they adapt to the type of cables connected to them. The Auto MDI/ MDIX feature only works when the unit are configured in auto detect mode,
which is the default mode.
Pin Name
Description
TIA/EIA 568A TIA/EIA 568B
1
Bl_DA+/Tx+ Bi-directional pair A+ (T) white/green
white/orange
2
Bl_DA-/Tx- Bi-directional pair A- (Transmit-)
green
orange
3
Bl_DB+/Rx+ Bi-directional pair B+ (R) white/orange white/green
4
Bl_DC+
Bi-directional pair C+
blue
blue
5
Bl_DC-
Bi-directional pair C-
white/blue
white/blue
6
Bl_DB-/Rv- Bi-directional pair B- (Receive -)
orange
green
7
Bl_DD+
Bi-directional pair D+
white/brown
white/brown
8
Bl_DD-
Bi-directional pair D-
brown
brown
LED Name
Description
A
Speed
OFF: 10 Mbps
Green: 100 Mbps
Yellow: 1000 Mbps
B
Link (activity)
Green, blinking, variable rate: Network traffic
Green, steady On: No network traffic
OFF: Not connected
Top
PRI Connection (RJ-48)
Caution: Always use standard telecommunication cables with a minimum of 26 AWG wire gauge.
PRI connections use two pairs of wires: one pair for transmission and the second pair for reception. It is wired so that pins 1 and 2 are on one twisted pair
and pins 4 and 5 are on a second pair according to common wiring standards which meet the TIA/EIA 568A and 568B requirements.
Note: The Mediatrix unit PRI ports can be used as a T reference point, but not as U reference points (2-wire). Never connect a U PSTN line or a U TE into
the Mediatrix unit PRI ports.
Pin # NT Mode
TE Mode
1
Transmit #2 (+) Receive #2 (+)