![MEDAP 5752 3712 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/medap/5752-3712/5752-3712_operating-instructions-manual_1759329011.webp)
Introduction
Basic requirements
GA 5752 3125 GB 10
11
1
The product is:
Active
Sterility:
Not a sterile product
Single-use product /
reprocessing:
The device and parts of the accessories are reusable. For
information on reprocessing, cleaning and disinfection, please see
the operating instructions.
1.5.4
Versions of FINA fine regulator VAC
The connection of the terminal unit to FINA FRV VAC depends on the model being used:
Version A: Tapping unit with integrated gas pin
• FINA FRV VAC is fitted directly to the terminal unit.
Version B: Tapping unit with rail clamp and NIST connection
• FINA VAC is designed for mounting onto an equipment rail 25 x 10 mm and is supplied via a
NIST connection with vacuum from a terminal unit connected using a connection tube with gas
probe.
Products and accessories are only permitted with ISO colour coding. In Germany, Austria and
Switzerland, products with neutral colour coding are also permitted.
NOTE
The products are supplied with ISO coding. The scope of delivery includes a label
for neutral colour coding.
The product is available in the following versions:
• FINA fine regulator VAC Wall MEDAP (REF 5752 3712)
• FINA fine regulator VAC Wall DIN (REF 5752 3713)
• FINA fine regulator VAC equipment rail (REF 5752 3714)
1.5.5
Interface description
All devices and accessories which are combined with the tapping unit must be listed in the
accessories list or meet the specifications of the interface description. Configuration of the overall
system as well as functional testing are subject to the overall responsibility of the medical staff.
Functionality and suitability of the connected accessory for each intended application must be
checked by the operator before every use. This includes the functionality of the connector
components, airtightness and suitability regarding material properties, working pressure and flow
rate.
1.5.5.1
Dimensions for the gas type specific connection for compressed gas
The dimensions for plugs or terminal units are subject to national standards DIN 13260-2
(Germany) and MEDAP standard, depending on the product type.
1.5.5.2
Vacuum connection tube
The vacuum connection tube is used to connect the hydrophobic bacterial and viral filter with the
septic fluid jar cap.
Technical specifications
• Shore hardness of 60
• Inside diameter 6 mm
• Length 50 cm (± 10 cm)
• Vacuum resistant down to -95 kPa (must not collapse)