WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result caus-
ing property damage, personal injury, or loss of life.

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any
other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use

any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier, call the

fire department.

— Installation and service must be performed by

a qualified installer, service agency, or the gas
supplier.

WARNING: Improper installa-
tion, adjustment, alteration, ser-
vice, or maintenance can cause
injury or property damage. Re-
fer to this manual for correct
installation and operational pro-
cedures. For assistance or ad-
ditional information consult a
qualified installer, service
agency, or the gas supplier.

WARNING: This is an unvented
gas-fired heater. It uses air
(oxygen) from the room in
which it is installed. Provisions
for adequate combustion and
ventilation air must be pro-
vided. Refer to 

Air for Com-

bustion and Ventilation on
page 4 in this manual.

VENT-FREE NATURAL GAS HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

MBN10TLA

This appliance may be installed in an aftermarket*, permanently located, manufactured
(mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Содержание MBN10TLA

Страница 1: ...n adjustment alteration ser vice or maintenance can cause injury or property damage Re fer to this manual for correct installationandoperationalpro cedures For assistance or ad ditional information co...

Страница 2: ...tilation to run properly This heater has an oxygen depletion sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilatio...

Страница 3: ...ton 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater UNPACKING PRODUCT FEATU...

Страница 4: ...perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to areas such as...

Страница 5: ...ect vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used __________...

Страница 6: ...gtheatticwillactivatethepowervent Figure 2 Ventilation Air from Inside Building Or Remove Door into Adjoining Room Option 3 Ventilation Grills Into Adjoining Room Option 2 12 12 Ventilation Grills int...

Страница 7: ...c candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls WARNING Never install the heater in a bathroom in a recreational vehicle where curtains furniture clothing or ot...

Страница 8: ...ont panel at this time Replace front panel after making gas connections and checking for leaks see pages 9 and 10 Figure 10 Removing Front Panel Of Heater Figure 6 Folding Anchor Figure 7 Popping Open...

Страница 9: ...hem from going into heater controls If sediment trap is not installed or is installed wrong heater may not run properly IMPORTANT Holdpressureregulatorwith wrench when connecting it to gas piping and...

Страница 10: ...bbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operating Heater pages 10 and 11 Check the rest of the internal joints for leaks 7 Turn off heater see To Turn Off Gas To Appli...

Страница 11: ...inute before lighting pilot again 8 Turn control knob counterclockwise C clockwise to desired heating level The main burner should light Set control knob to any heat level between HI and LO CAUTION Do...

Страница 12: ...rmocouple to cool When the thermocouple cools the heater will shut down If pilot flame pattern is incorrect as shown in Figure 18 turn heater off see To Turn Off Gas to Appliance page 11 see Troublesh...

Страница 13: ...le connection loose at con trol valve 6 Pilot flame not touching thermocouple which allows thermocouple to cool causing pilot flame to go out This prob lem could be caused by one or both of the follow...

Страница 14: ...ct local natural gas company 3 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is re...

Страница 15: ...ge 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventilation air OBSERVED PROBLEM Heater produces a...

Страница 16: ...16 105728 VENT FREE NATURAL GAS HEATER MBN10TLA ILLUSTRATED PARTS BREAKDOWN MBN10TLA 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 16 17 18 21 22 24 14 20 23 19 12 1 12 2 ODS PILOT...

Страница 17: ...1 8 M11084 38 Screw 8 x 3 8 8 9 098352 03BR Deflector Unit 1 10 098271 03 Ignitor Cable 1 11 098249 01 Nut M5 2 12 100701 03 ODS Pilot Assembly 1 12 1 098514 01 Thermocouple 1 12 2 098594 01 Ignitor E...

Страница 18: ...NT PARTS EQUIPMENT SHUTOFF VALVE GA5010 Equipmentshutoffvalvewith1 8 NPTtap ACCESSORY Purchasetheseheateraccessoriesfromyour local dealer If they cannot supply this ac cessories either contact Cans Un...

Страница 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 20: ...the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper ma...

Отзывы: