background image

EN 13241
EN 12453
EN 12445

APROLI 480

Oil-hydraulic operator

for tilt-up doors with counterbalance

   1 - 16

GB

Instructions manual

pages

the gate opener

istr_aproli480_GB.ai   1   26/09/2018   15:59:23

Содержание APROLI 480

Страница 1: ...EN 13241 EN 12453 EN 12445 APROLI 480 Oil hydraulic operator for tilt up doors with counterbalance 1 16 GB Instructions manual pages the gate opener...

Страница 2: ...ning about the presence of an automated installation The installer must inform and instruct the end user about the proper use of the system by releasing him a technical dossier including layout and co...

Страница 3: ...rbalanced tilt up doors on residential applications It is compact and being oil hydraulic it has all the advantages that such technology can ensure ie reliability smooth movements adjustable thrust po...

Страница 4: ...53 radio transmitter 11 DGT 61 main PC board Pic 2 Pic 3 ELECTRICAL GENERAL WIRING DIAGRAM AND COMPONENTS LAYOUT Before installing Aproli 480 it is recommended that all of the essential safety and com...

Страница 5: ...any friction points IMPORTANT consider that Aproli 480 and the hardware require extra counterweight to compensate the additional weight so that the door once automated and released for manual operati...

Страница 6: ...is recommended that the space between the arms be 20 25 mm approx Curved arms are to be used when there is not enough space to install them next to the existing arms of the door Pic 7 Movement arm of...

Страница 7: ...door in closed position rotate the operator shaft by approx 5 degrees clockwise The door will so get a constant pushing action to stay securely closed English IMPORTANT once Aproli 480 has been instal...

Страница 8: ...with the tubular bars It is recommended that the telescopic arms be lubricated along the sliding surface into the tubular section Fasten the telescopic arms to the fixing plates Fix the lateral suppo...

Страница 9: ...t the movements are performed in a very smooth way without any friction First make sure that Aproli 480 be released for the first manual test and be well balanced Add extra counterbalance if necessary...

Страница 10: ...been properly balanced as explained before no power adjustment is required English Should the operator shaft rotate in the opposite direction swap the live 10 and 12 230 V 50 Hz 6 F 230 V 50 Hz blue c...

Страница 11: ...o terminals 5 and 6 of Elpro 6 exp control board Elpro 6 exp Pic 18 INSTALLATIONS WITH PEDESTRIAN DOOR With those installations where a pedestrian door is fitted two Aproli 480 operators are required...

Страница 12: ...English 12 Oil hydraulic operator for tilt up doors with counterbalance APROLI 480...

Страница 13: ...English 13 Oil hydraulic operator for tilt up doors with counterbalance APROLI 480...

Страница 14: ...English 14 Oil hydraulic operator for tilt up doors with counterbalance APROLI 480...

Страница 15: ...erator model Dimensions per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services in...

Страница 16: ...C 80 C Operating torque 220 300 Nm Shaft rotation max 205 Oil type Oil Fadini Item 708L Weight of operator 11 kg Weight of Aproli 480 w c accessories 24 kg Door surface 7 m 40 C with specific optiona...

Отзывы: