Page 39
84RT Seres Speed Level™ - Operator’s Manual
July 2021
Secton 12 - Component Locatons
Upper Controls
ART_4295
91843
Emergency Stop
Joystick
Enable Bar
Lift / Drive
Steering
Speed / Torque
Automatic Leveling
Horn (Optional)
Manual Level Switches
8
11
Start Switch 5
12
1
2
3
4
Overload Indicator 6
7
13
Work Lights (Option)
10
Preheat (Diesel)
Choke (Dual Fuel)
9
Control
Description
1
Joystick
DRIVE
Controls Forward and Reverse travel at stepped speeds.
LIFT
Move toward operator to elevate platform. Lift speed increases
proportional to the joystick movement. Will not function if tilt alarm is
on.
Move away from operator to lower platform. Speed is fixed.
2
Enable Bar
Squeeze to enable DRIVE, STEER, and LIFT from joystick.
3
Steering Switch
Using thumb, press and hold the rocker switch to steer Left or Right.
4
Lift/Drive Selector
Select LIFT or DRIVE function for joystick.
5
Start Switch
Turn to start engine. Switch will return to RUN position for normal operation.
Turn to OFF to shut engine down.
6
Overload Indicator
Light ON and audible alarm indicates platform overloaded.
7
Speed / Torque
Switch
HIGH TORQUE
Slow speed. Provides maximum torque for rough terrain.
MID RANGE
Mid speed. Provides medium torque for smooth to moderate terrain.
HIGH SPEED
Provides high speed when platform height is below 10 feet (3 m).
8
EMERGENCY STOP
Switch
PUSH to stop all machine functions.
TURN CLOCKWISE to reset.
9
Choke/Preheat
Operate when starting in cold start conditions.
10
Work Lights (Option)
Turns on work lights.
11
Horn (Option)
Press to sound warning horn.
12
Automatic Level
Switch
Move switch DOWN and hold until automatic leveling is complete.
Tilt alarm will turn off when platform is level.
13
Manual Level
Switches
Move the upper switch to the left to LOWER the front of the platform.
Move the upper switch to the right to RAISE the front of the platform.
Move the lower switch to the left to move the platform to the LEFT.
Move the lower switch to the right to move the platform to the RIGHT.