Page 36
84RT Seres Speed Level™ - Operator’s Manual
July 2021
Secton 11 - Mantenance
Lubrication
Operator may perform routine maintenance only. Lubrication listed as Scheduled Maintenance must
be performed by a qualified service technician.
ART_3085
1
3
3
2
5
4
No�����
Item
Specification
Frequency
1
Hydraulic
Reservoir
Mobile Fluid DTE 10, DTE 13 M, or
AW32
Do not substitute with lower grade
fluids as pump damage may
result.
Fill to the middle of the sight gauge
with platform in the stowed position.
Routine Maintenance
Check Daily
Scheduled Maintenance
Change yearly or every 1000 hours, whichever occurs first
2
Hydraulic
Filter
Filter Element
Scheduled Maintenance
Normal Conditions
Change every six months or 500 hours, whichever occurs
first
Severe Conditions
Change every three months or 300 hours, whichever
occurs first
3
Tilt
Cylinders
Pivot
Points
Lithium N�����L�����G����� #2 EP
Purge old grease
Scheduled Maintenance
Normal Conditions
Apply every 6 months or 500 hours, whichever occurs first
Severe Conditions
Apply every 3 months or 250 hours, whichever occurs first
4
Boom
Gear
High copper content anti-seize
compound�����
Apply new grease
Scheduled Maintenance
Normal Conditions
Apply every 1 months or 100 hours, whichever occurs first
Severe Conditions
Apply every 2 weeks or 50 hours, whichever occurs first