background image

MSI

5200C

BANTAM
PORTABLE VEHICLE
WEIGHING SYSTEM

User

Guide

Quality
Industrial
Weighing
and Force
Measurement
Equipment

Measurement
Systems
International

Содержание MSI5200C

Страница 1: ...MSI5200C BANTAM PORTABLE VEHICLE WEIGHING SYSTEM User Guide Quality Industrial Weighing and Force Measurement Equipment Measurement Systems International ...

Страница 2: ...to Set Up and Operate the System 5 Battery Operation 5 External AC Operation 6 External DC Operation 6 Calibration Procedure 7 Internal Zero Adjustment 8 Battery Charging 9 Battery Replacement 9 Troubleshooting Guide 11 Parts List 13 Figures 14 The MSI Limited Warranty 17 Important Information Please read the following instructions completely before using the Magnum ...

Страница 3: ... C Cable Used for D C system operation WARNING Do not connect the Bantam to 28 Volt D C external power sources Weigh Pad Used in any order and in any number maximum of six for weighing operations METER Used for weight indication Contains an internal battery and battery charger Operates from external 117 Volts 10 A C external 12 Volts D C 1 Amp or internal battery power sources On Off Switch Turns ...

Страница 4: ...s to flash 1 2 hour of battery life remains considerably less if optional printer is in use Automatic Shutoff When the internal battery is fully discharged and the external power is not connected the internal battery will be automatically disconnected to protect the battery Zero Switch Push to zero meter prior to loading weigh pads or checking calibration CAL Switch With no load on the weigh pads ...

Страница 5: ...lor of pad connector at each connec tion CAUTION Snap cable strain reliefs to eyelets in weigh pad handles 3 Turn the meter ON OFF Switch to ON Verify that all display segments and lamps light during the segment check 88888 Wait until the program nunber has been displayed and a stable reading appears on the display 4 With the weigh pads unloaded push the ZERO Switch to zero the display 5 To check ...

Страница 6: ...directly from 117 Volt 10 6OHz A C external power sources 1 Turn the ON OFF Switch to OFF 2 Connect cable 40035 6 to the connector on the side of the meter labeled POWER CAUTION Ensure proper pin alignment Do not attempt to force connector into place 3 Plug Cable 40035 6 into external A C power source 4 Operate system as in Battery Operation steps 1 8 EXTERNAL D C OPERATION The Bantam may be opera...

Страница 7: ...m those obtained at a certified scale Note The Battery should be fully charged for this operation 1 Turn the ON OFF switch to on verify that all display segments and lamps are on during the segment check then off again before the program number is displayed P XX 2 With no load on the weigh pads wait for a stable display reading and push the zero switch to zero the display 3 Push the Cal Switch The...

Страница 8: ...nt Systems International Inc will calibrate for a fixed charge systems that are returned to the factory Systems must be returned freight prepaid INTERNAL ZERO ADJUSTMENT If the display reading is greater than a few percent of the system weight capacity when the meter is first turned on with no weight on the pads you may want to internally re zero the meter as part of the system calibration procedu...

Страница 9: ...ld be in the OFF position for fastest charging The internal battery may be allowed to charge continuously A fully discharged battery will reach 80 90 of full capacity within 16 hours if the ON OFF switch is in the OFF position Frequent recharging will give the longest battery service life Poorest service life is obtained when the battery is allowed to fully discharge before each recharge A fully c...

Страница 10: ...y is required since the plate cannot be removed Unplug all wires going to the power pad and printer connectors on the right side of the meter case The four nuts inside the feet on the bottom of the meter case The entire internal chassis assembly may now be removed from the case Unplug the battery and slide out sideways without removing the battery hold down plate 4 Install the new battery and reas...

Страница 11: ...r board Scale capacity is exceeded Loose or disconnected weigh pad cable Internal zero adjust control on computer board needs adjustment Defective computer board Defective weigh pad Damaged or broken weigh pad or meter cable ACTION Recharge Remove front panel and dis connect internal battery If charge lamp comes on with A C power connected Battery is probably defective Check Fuse s on Power supply...

Страница 12: ...omputer board Defective weigh pad Check items above Internal zero adjust control on Computer Board needs adjustment Defective weigh pad Damaged or broken weigh pad or meter cable External DC power source voltage too low ACTION Check cables Same as above Replace Connect to one pad at a time to isolate faulty pad Same as above Adjust per calibration procedure Connect each weigh pad individually to m...

Страница 13: ... 4 40035 6 AC Power Cable 1 1 1 1 40043 240 DC Power Cable 1 1 1 1 D00020 Weigh Pad 2 3 4 6 D00652 1 Meter 120 VAC 1 1 1 1 D00652 2 Meter 230 VAC 1 1 1 1 D00652 3 Meter 120 VAC Printer Option 1 1 1 1 D00652 4 Meter 230 VAC Printer Option 1 1 1 1 Meter Replacement Parts Recommended Spare Parts Quantity Recommended D00653 1 Display Board 1 D00654 1 Computer Board 1 35910 01 Battery 1 D00655 Chassis ...

Страница 14: ... T E M S I N T E R N A T I O N A L Page 14 MSI 5200C Bantam Vehicle Weighing System User Guide SEAL ACCESS PLUG 1 2 3 4 5 6 24 24 24 24 14 15 METER FIGURES Figure 1 Access to calibration port Figure 2 Six pad system configuration ...

Страница 15: ...Weighing System User Guide Page 15 M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L 1 2 15 METER 14 1 2 3 4 24 14 or 24 15 METER 14 or 24 Figure 3 Four pad system configuration Figure 4 Two pad system configuration ...

Страница 16: ...e etc Including bare wire Step 2 Slip shrinkable tubing on each insulated wire Step 4 Solder bare wire Step 5 Solder remaining wires Step 6 Slip tubing over each solder joint Apply heat shrink Cable may or may not have a shield Remove shield from repair area when making splice Step 7 Wrap splice with barrier E press firmly to seal joint with electrical tape Step 8 Fold cable as shown and tie with ...

Страница 17: ...airs or alterations made by others except those repairs or alterations made with its specific written consent nor shall the Company be liable for any damages or delays whether caused by defective workmanship materials or otherwise The Company shall not be liable for any personal injury or property damage resulting from the handling possession or use of the equipment by the customer The warranty se...

Страница 18: ...ement Systems International PUB 138 07 90 Printed in U S A Measurement Systems I N T E R N A T I O N A L 14240 INTERURBAN AVENUE SOUTH SEATTLE WASHINGTON 98168 4660 U S A 206 433 0199 FAX 206 244 8470 MADE IN THE USA ...

Отзывы: