USB-1208HS User's Guide
Specifications
20
Power
Table 11. Power specifications
Parameter
Condition
Specification
Operating modes
Bus-powered, USB 5 V supply
Supply current
(see Note 1)
Suspend mode
<2.5 mA
Enumeration
<100 mA
Run mode
<500 mA
Power consumption
excluding digital outputs
Run mode
1.05 W max (210 mA input current)
Power available for +5 V,
AICKO, TMR, and
digital I/O
Run mode
1.45 W max
The total power consumption for all external loads must be less than this
value, and each load must meet the individual specification for the
terminal.
Digital output power
calculation
Power per output = Iout × 5 V
(for example, @ 24 mA, P = 0.024 × 5 = 120 mW / output)
+5 V output power
calculation
Power (W) = Iout × 5 V
+5 V output voltage
range (see Note 2)
Run mode
4.25 V min, 5.25 V max
Suspend mode,
enumeration
0 V
+5 V output current
Run mode, no
other output loads
290 mA max (1.45 W)
Fuses
On USB supply
Mount Fuse.
Spare fuse mounted in holder on PCB.
Note 1:
This is the total current consumption for USB-1208HS, inc5 V and digital output currents.
Note 2:
Output voltage range assumes input power is within specified limits.
USB specifications
Table 12. USB specifications
Parameter
Specification
USB device type
USB 2.0 (high-speed)
USB device compatibility
USB 1.1, 2.0
USB cable length
5 m (16.40 ft) max
USB cable type
A-B cable, UL type AWM 2725 or equivalent (min 24 AWG VBUS/GND,
min 28 AWG D+/D–).
Environmental
Table 13. Environmental specifications
Parameter
Specification
Operating temperature
range
0 °C to 50 °C
Storage temperature
range
–40 °C to 85 °C
Humidity
0% to 90% non-condensing