background image

 
 

 

MEANWELL 

DC/AC  

POWER INVERTERS

 

 

A301/A302-1K0 = 1000 Watts 
A301/A302-1K7 = 1500 Watts 
A301/A302-2K5 = 2500 Watts 

 
 

A301 = 12VDC input 
A302 = 24VDC input 

230VAC output 

Don't 

disassemble 

Keep away from 

moisture 

Keep away from 

fire & heat 

Don't stack 

inverters 

Maintain good 

ventilation 

Содержание A301-1K0

Страница 1: ...A302 1K0 1000 Watts A301 A302 1K7 1500 Watts A301 A302 2K5 2500 Watts A301 12VDC input A302 24VDC input 230VAC output Don t disassemble Keep away from moisture Keep away from fire heat Don t stack in...

Страница 2: ...ockets Twin power outlet sockets Temperature controlled automatic cooling fan ON OFF remote control optional SPECIFICATIONS Part No A301 A302 1K0 A301 A302 1K7 A301 A302 2K5 Input Voltage 12V 24V Batt...

Страница 3: ...300 200 200 200 100 100 100 0 0 0 100 100 100 200 200 200 300 300 300 400 400 400 MAINS POWER SINEWAVE MODIFIED SINE WAVE TRUE SINE WAVE Logically it follows that the process used in a TSW inverter is...

Страница 4: ...he inverter Part No A301 A302 1K0 A301 A302 1K7 POWER FAULT LIGHTS AC OUTPUT SOCKETS FAN DC CABLE ENTRY POWERON SWITCH FRONT REAR Supplied Operating instructions Negative Black DC connectionleadfitted...

Страница 5: ...e inverter a suitable 12V or 24V DC power supply is required This can be vehicle or caravan batteries a portable power pack or battery bank joined in series and or parallel to produce 12V or 24V DC Fo...

Страница 6: ...ell inverters are designed FOR INDEPENDENT USE ONLY The inverter cannot be connected to household wiring whether the building is connected to the electricity grid or not The 1000W and 1500W inverters...

Страница 7: ...run close together to reduce cable inductance The cables should also be protected from any damage Any connections should be made securely using the proper hardware Procon Technology recommends the use...

Страница 8: ...d if this occurs This prevents damage to the inverter batteries and or appliance being powered Low Battery This feature will sound an alarm when the battery system powering the inverter is low It is r...

Страница 9: ...efore resuming operation If possible reduce the load on the inverter and improve ventilation DETERMINING SUITABLE LOADS APPLIANCES The inverter is fitted with 2 approved AS NZS Australian socket outle...

Страница 10: ...rter will not run my appliance even though the appliance label indicates that it draws less power than the size of the inverter A Electrical appliances can be divided into three groups by the way they...

Страница 11: ...GND the inverter see the section on Earthing Q Can I run fluorescent lighting from myinverter A Most portable fluorescent work lamps should operate fine on an inverter even though they may be slow to...

Страница 12: ...t of the motor and allow an appliance to be used with an inverter where otherwise it would cause it to overload Q Can I run a laptop computer A Most laptop notebook computer AC power adapters work per...

Страница 13: ...AIMER All specifications are subject to change without notice Any circuit diagrams or assembly diagrams provided with equipment are for reference purposes only Procon Technology makes no representatio...