168
MDS entraNET System Guide
MDS 05-4055A01, Rev. C
7.1.3 Using Logged Operation Events
(See
Event Log Menu
on Page 81)
The transceiver microprocessor monitors many operational parameters
and logs them as various classes of “events.” If the event is one that
affects performance, it is an “alarmed” event. There are also normal or
routine events such as those marking the restarting of the system, imple-
mentation of parameter changes, and external access to the entraNET
MS. Informational events are stored in temporary (RAM) memory that
is lost in the absence of primary power, and alarms are stored in perma-
nent memory (flash memory) until cleared by your request.
Table 3-3
summarizes these classifications.
These events are stored in the transceiver Event Log, and can be a valu-
able aid in troubleshooting radio problems or detecting attempts to
breach network security.
Table 7-5
lists all of the transceiver event codes and provides a brief
description of their meaning.
Table 7-4. Event Classifications
Level
Description or Impact
Storage
Informational
Normal operating activities
Flash
Memory
Minor
Does not affect radio operation
RAM
Major
Degraded radio performance but
still capable of operation
RAM
Critical
Prevents the radio from
operating
RAM
Table 7-5. MDS entraNET Event Codes
Index
Event Type
Event Name
String
Clear String
Set String
0
EVENT_IPADDR
IP Address
Valid
Invalid
1
EVENT_IPMASK
IP Mask
Valid
Invalid
2
EVENT_MACADDR
MAC Address
Valid
Invalid
3
EVENT_SYSTEM_ERROR
System Error
Cleared
Please
Reboot
4
EVENT_BRIDGE
Network
Interface
OK
Error
5
EVENT_FREQ_CAL
Frequency
Calibrated
Not
Calibrated
6
EVENT_POWER_CAL
Power
Calibrated
Not
Calibrated
7
EVENT_FLASH_TEST
Flash Test
Passed
Failed
8
EVENT_RSSI_CAL
RSSI
Calibrated
Not
Calibrated
9
EVENT_RAD_NO_NETWORK_
ADDRESS
Net Address
Programmed
Not
Programmed
Содержание entraNET 2400
Страница 8: ...vi MDS entraNET System Guide MDS 05 4055A01 Rev C LA N CO M1 CO M2 PW R LIN K...
Страница 10: ...2 MDS entraNET System Guide MDS 05 4055A01 Rev C LA N CO M1 CO M2 PW R LIN K...
Страница 22: ...14 MDS entraNET System Guide MDS 05 4055A01 Rev C LA N CO M1 CO M2 PW R LIN K...
Страница 24: ...16 MDS entraNET System Guide MDS 05 4055A01 Rev C LA N CO M1 CO M2 PW R LIN K...
Страница 36: ...28 MDS entraNET System Guide MDS 05 4055A01 Rev C LA N CO M1 CO M2 PW R LIN K...
Страница 106: ...98 MDS entraNET System Guide MDS 05 4055A01 Rev C LA N CO M1 CO M2 PW R LIN K...
Страница 108: ...100 MDS entraNET System Guide MDS 05 4055A01 Rev C LA N CO M1 CO M2 PW R LIN K...
Страница 126: ...118 MDS entraNET System Guide MDS 05 4055A01 Rev C LA N CO M1 CO M2 PW R LIN K...
Страница 128: ...120 MDS entraNET System Guide MDS 05 4055A01 Rev C LA N CO M1 CO M2 PW R LIN K...
Страница 150: ...142 MDS entraNET System Guide MDS 05 4055A01 Rev C LA N CO M1 CO M2 PW R LIN K...
Страница 152: ...144 MDS entraNET System Guide MDS 05 4055A01 Rev C LA N CO M1 CO M2 PW R LIN K...
Страница 170: ...162 MDS entraNET System Guide MDS 05 4055A01 Rev C LA N CO M1 CO M2 PW R LIN K...
Страница 180: ...172 MDS entraNET System Guide MDS 05 4055A01 Rev C LA N CO M1 CO M2 PW R LIN K...
Страница 182: ...174 MDS entraNET System Guide MDS 05 4055A01 Rev C LA N CO M1 CO M2 PW R LIN K...
Страница 198: ...190 MDS entraNET System Guide MDS 05 4055A01 Rev C LA N CO M1 CO M2 PW R LIN K...
Страница 206: ...I 2 MDS entraNET System Guide MDS 05 4055A01 Rev B...