Water
Problem
Possible Cause
Remedy
Pump not working (no noise)
No power from control panel
Check circuit breaker
Flat Battery
Charge battery
Faulty pressure switch
Replace pump, Contact dealer for
replacement
Bad electrical connection
Check connections with multimeter
or test light
Pump working but no water flow
Airlock in water lines
Turn on tap and hold finger over
nozzle for 5 seconds and release.
Repeat several times. If this fails, fill
water tank and use mains pressure
to pressurize tank
Water tank is empty
Fill water tank
Kinked hose
Check hoses ensuring none are
fouled
Damaged / worn pump diaphragm Repair or replace pump
Gas
Problem
Possible Cause
Remedy
Cooker not igniting
Gas bottle empty
Fill gas bottle
Gas bottle not turned on
Turn on valve on gas bottle
Gas hose on cooker not connected Check bayonet is securely
connected into receiver
Regulator blocked
Check regulator is not blocked with
dirt, wasps nests etc
Kinked hose
Check hose is not twisted and
kinked
•
Remember that first use after connecting gas will take a little while for the gas to purge the line to
the cooktop. Hold the control knob down for up to 4 minutes
Содержание XT16HR ISLAND 2022
Страница 44: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 42...
Страница 54: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 52 12 Volt Wiring Diagram Main Circuit...
Страница 55: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 53 Wiring Diagram Switch Panel...
Страница 73: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 71 Fig 1...
Страница 87: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 85 Hub Assembly...
Страница 88: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 86 Trailing Arm Bushes...
Страница 116: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 114...