44
Removing The Cowl Cover
•
Grab the handle of the cowl cover.
•
Press the palm against the lid (Fig.3a - 1) while pulling the lid off the cowl (Fig.3a - 2).
Select Water Heater Mode
Use the control panel to select the water heater mode
a = Red indicator lamp “Fault”
b = Water heater “On” 60 °C or 70 °C
c = Water heater “Off”
If there is air in the gas sup
ply line, it may take up to a minute before the gas is available for combustion. If the
appliance switches to “Fault” during this time, switch off the appliance
– wait 10 minutes –
and switch on again!
When using the vehicle switches
Refer to
operating instructions of the vehicle manufacturer or see switch labels.
Switching Off Gas Operation
–
Switch off the water heater to position (Fig. 3b
- c).
If the water heater is not to be used for a longer period, mount cowl cover (non-observance of this point can lead
to the function of the appliance being impaired through water, dirt or insects), close stop cock valve in the gas
supply line and close the gas cylinder.
Before setting off on any journey, fit cowl cap with the Truma UltraRapid switched off. Please ensure
that it is secure and has locked into place (risk of accident). Defective cowl caps must not be used.
Drain the water heater if there is a
risk of frost! Warranty claims will not be accepted if this is ignored.
R
ed Indicator Lamp “Fault”
The red indictor lamp (a) lights up if there is a fault. For possible causes please refer to “Fault finding” on page 6. To
unlock, switch off the appliance,
wait 10 minutes, and switch on again.
Содержание XT12HR 2021
Страница 29: ...25 STEP 2 Lift the coupling up o the tow pin...
Страница 34: ...30...
Страница 41: ...37 Hub Assembly...
Страница 42: ...38 Trailing Arm Bushes...
Страница 51: ...47 12 Volt Wiring Diagram...
Страница 64: ...60 Trip Name Date Km Start Km Finish Cumulative Km...