Solar Charging
Symptom
Possible Cause
Remedy
No solar power DC to DC solar light
not showing
Tripped circuit breaker
Reset circuit breaker CB6 in Fig. 1 &
Fig. 3
DC to DC overloaded
Reset DC to DC by disconnecting
from battery and solar input. See
Projector user guide.
No solar power Dc to DC solar light
showing
Tripped circuit breaker
Reset circuit breaker CB4 in Fig. 1 &
Fig. 3
Weak solar charging (low voltage
output)
Weak solar input due to shade
Move to sunnier area
Weak solar due to dirty panels
Clean panels
Incorrect setting
Ensure DC to DC is set to correct
battery type
Solar charging not meeting demands Power demands exceeding
designed solar output
Add additional solar panels
Reduce load
NOTES*
Expectations of a 300 watt solar charging system need to be reasonable. Running two fridges without adding
additional solar and following best practice with pre-cooling and packing will greatly reduce battery life and the ability
of the solar panels to keep up with power needs.
Using inverters will very quickly diminish battery capacity.
Charging from Tow Vehicle
Symptom
Possible Cause
Remedy
No charge Alternator light not
showing on DC to DC
Tripped breaker
Reset circuit breaker CB5 in Fig. 1 &
Fig. 3
Tripped breaker in car circuit
Check car circuit breaker/fuse Fig. 6
No charge, alternator, and solar light
both on
Trigger wire for DC to DC unit not
activated
Connect trigger wire for DC to DC to
accessory power from car via trailer
plug. Fig. 5
No charge DC to DC alternator lit
Tripped breaker
Reset circuit breaker CB4 Fig. 1 &
Fig. 3
Trigger wire for DC to DC unit not
activated for smart alternator
Connect trigger wire for DC to DC to
accessory power from car via trailer
plug. Fig. 5
Содержание XT 12E
Страница 45: ...www marketdirect com au IPh 1300 494 494 IP a g e 45...
Страница 55: ...www marketdirect com au IPh 1300 494 494 IP a g e 55 12 Volt Main Circuit Diagram...
Страница 56: ...www marketdirect com au IPh 1300 494 494 IP a g e 56 12 Volt Switch Circuit...
Страница 74: ...www marketdirect com au IPh 1300 494 494 IP a g e 74 Fig 1...
Страница 86: ...www marketdirect com au IPh 1300 494 494 IP a g e 86 Trip Name Date Km Start Km Finish Cumulative Km...
Страница 88: ...www marketdirect com au IPh 1300 494 494 IP a g e 88 Hub Assembly...
Страница 89: ...www marketdirect com au IPh 1300 494 494 IP a g e 89 Trailing Arm Bushes...
Страница 114: ...www marketdirect com au IPh 1300 494 494 IP a g e 114 Video Tutorials...