McQuay Incremental MQT Series Скачать руководство пользователя страница 5

IM 354 / Page 5

Panel and Thin Wall Application
1. Install the subbase as described in the subbase installa-

tion section.

2. Install the louver frame as described in the louver frame

installation section.

3. Position the room cabinet/wall sleeve in the louver frame

opening and on the subbase. The rear face of the cabinet
should be recessed from the outside edge of the louver
frame by the depth of the louver to be installed (Figure 7).

4. Remove the rectangular knockout in the base pan of the

wall sleeve.

5. Adjust the subbase leveling bolts so the room cabinet/

wall sleeve is level or tilted a maximum of 

1

8

" (3mm)

downward to the outside. Secure the room cabinet/wall
sleeve to the subbase with the two long screws retained
from the subbase assembly (see Figure 4).  Holes, 

5

32

"  in

diameter, have been added to each side of the room
cabinet/wall sleeve as a provision for securing the sleeve
in the wall opening. Each hole is located 2" (51mm) down
from the top  and 2" (51mm) in from the rear of the sleeve.
These holes or other non-perforated locations in the sides
and/or top of the sleeve may be used to fasten the sleeve
to the wall from the inside. Never secure the room
cabinet/wall sleeve to the wall through the bottom.

6. Caulk the outdoor joint between the conditioner and wall

opening or louver frame around the top, bottom, and both
sides. Do not permit caulking to block weep holes.

Masonry and Thick Wall Application
Preparation of Wall Opening — In new construction, the
room cabinet/wall sleeve can be built into the building wall as
construction progresses, or openings can be left for later
installation. A lintel must be used to support any brick or
masonry work above the conditioner.

1. For installations with an optional subbase, install the

subbase as described in the subbase installation sec-
tion.

2. Set the room cabinet/wall sleeve in soft mortar and

position it in the wall opening. The rear face of the
conditioner should be recessed from the outside edge of
the wall opening by the depth of the louver to be installed
(see Figure 8). The center of gravity of the conditioner is
9

1

2

" (241mm) from the rear face. For wall mounted

conditioners, the center of gravity must be within the
load bearing portion of the wall; otherwise some method
of support is required.

3a. Installations without a subbase. Level or pitch the

room cabinet/wall sleeve a maximum of 

1

8

" (3mm) down-

ward to the outside. Holes, 

5

32

"  in diameter, have been

added to each side of the room cabinet/wall sleeve as a
provision for securing the sleeve in the wall opening.
Each hole is located 2" (51mm) down from the top  and
2" (51mm) in from the rear of the sleeve. These holes or
other non-perforated locations in the sides and/or top of
the sleeve may be used to fasten the sleeve to the wall
from the inside. Never secure the room cabinet/wall
sleeve to the wall through the bottom.

3b. Installations with an optional subbase. Adjust the

subbase leveling bolts such that the room cabinet/wall
sleeve is level or tilted a maximum of 

1

8

" (3mm) down-

ward to the outside. Secure the room cabinet/wall sleeve
to the subbase with the two long screws retained from
the subbase assembly (see Figure 4). Holes, 

5

32

"  in

diameter, have been added to each side of the room
cabinet/wall sleeve as a provision for securing the sleeve
in the wall opening. Each hole is located 2" (51mm) down

from the top and 2" (51mm) in from the rear of the sleeve.
These holes or other non-perforated locations in the
sides and/or top of the sleeve may be used to fasten the
sleeve to the wall from the inside. Never secure the room
cabinet/wall sleeve to the wall through the bottom.

4. Caulk outdoor joint between conditioner and wall opening

around the top, bottom and both sides. Do not permit
caulking to block weep holes.

3

3

8

"

(86mm)

Leveling Bolt

4" (102mm)

Cabinet Sleeve

Finished

Wall

Louver
Depth

Louver
Frame
(Optional)

Outside
Wall

Secure Cabinet

Sleeve To

Subbase

Finished

Floor

5

32

" (4mm) Dia.

(Typical of 2)

Subbase

(Optional)

2"

(51mm)

2"

(51mm)

Figure 7.

Outside
Wall

Louver
Depth

Mortar Base

5

32

" (4mm) Dia.

(Typical of 2)

Subbase

(Optional)

Finished

Floor

4" (102mm)

Min. 9"

(229mm)

Finished Wall

Lintel By

Others

Figure 8.

2"

(51mm)

2"

(51mm)

Содержание Incremental MQT Series

Страница 1: ...uh cooling 09 Nominal 9 000 Btuh cooling 11 Nominal 11 000 Btuh cooling 14 Nominal 14 000 Btuh cooling Vintage Designation B Sizes 06 09 11 C Size 14 Unit Type A Air conditioner with electric heat B Air conditioner with hydronic heat C Heat pump with supplemental electric heat MQT 09 B C 5 B Heater Code A 2 0 kW electric heat B 3 2 kW electric heat C 4 8 kW electric heat G Steam heat W Hot water h...

Страница 2: ...onal 3 8 10mm Louver Stamped Standard or 11 8 29mm Louver Extruded Optional 1 2 3 3 1 Note 4 minimum space requirement between underside of unit and floor for return air Subbase is optional on 208 and 230 volt units but standard on 265 volt A 3 4 19mm drip lip Optional condensate connection Figure 2 Conditioner wall mounted 93 4 248mm Min 4 102mm Min 2 x 4 51 x 102mm Junction Box All wiring should...

Страница 3: ... provided in the basepan of the wall sleeve for this purpose Optional Subbase Whenever a subbase is used it must be installed prior to the room cabinet wall sleeve The subbase provided in four pieces is adjustable from 43 8 to 155 8 111 to 397mm in depth to accommodate various projections of the conditioner into the room The standard subbase height is 4 102mm with adjustable leveling bolts to 41 2...

Страница 4: ...r building surface 3 Secure the louver frame to the wall through the sides and top of the sleeve Never secure the louver frame through the bottom Note The louver frame may also be secured from inside the room cabinet wall sleeve by screws driven through the sides and top of the louver frame sleeve Pre Installation Conditioner Preparation 1 Remove the outer carton of the room cabinet wall sleeve ch...

Страница 5: ... wall opening by the depth of the louver to be installed see Figure 8 The center of gravity of the conditioner is 91 2 241mm from the rear face For wall mounted conditioners the center of gravity must be within the load bearing portion of the wall otherwise some method of support is required 3a Installations without a subbase Level or pitch the room cabinet wall sleeve a maximum of1 8 3mm down war...

Страница 6: ...e assembly is 1 2 nominal copper tubing 5 8 O D actual The easiest method of connection would be with a short length of 5 8 I D flexible PVC tubing having a wall thickness of at least 1 8 3mm to prevent kinking or collapse however follow all local applicable codes Heating Cooling Chassis Installation 1 Slide the chassis into the room cabinet wall sleeve until firmly seated against the weather seal...

Страница 7: ...losed exerting sufficient pressure on the top black border area to allow the latching buttons to snap into place usually with an audible click 6 Replace the two sheetmetal screws adjacent to the latch ing buttons in the front panel 7 Replace the filter assembly at the bottom of the front panel Initial start up of the Incremental conditioners by an experi enced technician is usually the responsibil...

Страница 8: ...he original owner for one year Refrigerating circuits consist of the motor compressor assembly evapora tor coil condenser coil and interconnecting tubing Repairs under this warranty will be made at the Company s expense provided that the refrigerating circuit is delivered without shipping damage transportation prepaid to the factory or to a factory designated repair station at the Company s option...

Отзывы: