MCO Home MH9-CO2-WA Скачать руководство пользователя страница 1

             
                                                            www.mcohome.com                                    User Manual

 

MCOHome Technology Co., Ltd 

1

 

 

 

C

C

O

O

2

2

 

 

M

M

o

o

n

n

i

i

t

t

o

o

r

r

 

 

MH9-CO2-WA/WD 

 
                                                            Introduction                                                                       

 

MCOHome  CO2  Monitor  is  an  air  quality  detector  which  compatible  with  Z-Wave  Plus 

technology, it  is  mainly  used to  monitor  CO2 concentration in industrial, agricultural, and residence 

environment, while monitoring the indoor temperature, humidity and VOC air quality. Device can be 

included into any Z-Wave network, and is compatible with any other Z-Wave certified devices. 

 

                                                            Specification                                                                     

 

Power 

Supply

DC12V 

(WD);     

AC220V±10﹪  50/60HZ (WA) 

 

 

CO2 display range: 0-2000ppm 

 

Default threshold:1000ppm (adjustable) 

 

Temperature range

-9

50

℃(

15-122

℉)

 

 

Humidity range: 0%

99%RH 

 

Installation: Wall-mounted (Vertical) 

 

Work  environment:-10~+8

  0-90%RH   

(Non-condensation) 

 

Dimension

90* 130*28mm 

 

Hole Pitch

60mm or 82mm 

 

Housing: Tempered glass+ PC Alloy 

 

                                                        Safety Information                                                                         

 

To  protect  yourself  and  others  from  danger  and  to  protect  the  device  from  damage,  please  read  the 

safety information before using it. 

Important!   

 

A  qualified  electrician  with  the  understanding  of  wiring  diagrams  and  knowledge  of  electrical 

safety should complete installation following the instructions. 

 

Before  installation,  please  confirm  the  real  voltage  complying  with  the  device’s  specification. 

Cut off any power supply to secure the safety of people and device.   

 

During  installation,  protect  the  device  from  any  physical  damage  by  dropping  or  bumping.  If 

happens, please contact the supplier for maintenance. 

 

Keep the device away from acid-base and other corrosive solids, liquids, gases, to avoid damage. 

 

Avoid overexertion during operation, to protect device from mechanical damage. 

 

Read all instructions and documentation and save for future reference. 

 

                                                          Installation &Wiring                                                                 

Location: 

Device is suggested to be installed indoor, a place with around 1.5m height above the floor where 

represents the average CO2 concentration. It should be away from direct sunlight, any cover, or any 

heat source, to avoid false signal for temperature control. 

 