background image

 

 

Orolia Ltd, Silver Point, Airport Service Rd, Portsmouth, Hants, PO3 5PB, United Kingdom 

Tel: +44 (0) 23 9262 3900 Fax: +44 (0) 23 9262 3998 Email: 

[email protected]

  

 

Page | 1 

SERVICE BULLETIN 

Issue No:

  MG018 

 

 

 

Date:

   22

nd

 January 2016

 

McMurdo S20 & Kannad Marine R10 AIS MOB Devices 

Battery change & maintenance instructions 

  

INTRODUCTION 

1.1 Scope: 

This document provides the instructions to enable routine servicing 
of the S20 & R10 AIS MOB units. 

1.2 Servicing equipment: 

The following tools and equipment are required to carry out the 
servicing detailed in this manual.

 

Only authorised and trained 

people are allowed to perform maintenance & service on these products. We advise it is 
good practice that records of any maintenance or service performed are maintained.

 

Equipment: 

AIS receiver 

Hand tools: 

Calibrated torque driver with attachments: 60 cNm 

Small cross-headed screwdriver (No. 1 Pozidrive) 

1.3 Antistatic precautions:

 

The electronics section of the product is sensitive to electrostatic discharge (ESD) which can 
cause Immediate or hidden long term damage. It is important that the PCB is only handled 
under suitable Antistatic conditions. 

A fully grounded workstation, which has conductive surfaces to avoid the build-up of static 
charge, should be used. 

As a minimum, the operator must be connected to a good earth point through a resistance 
of 1MOhm. This is usually achieved by wearing a suitable wrist strap. 

1.4 Safety notices: 

The product has been assessed as presenting negligible hazard in a sealed serviceable state. 

 

 

Содержание Kannad Marine R10 AIS MOB

Страница 1: ...e advise it is good practice that records of any maintenance or service performed are maintained Equipment AIS receiver Hand tools Calibrated torque driver with attachments 60 cNm Small cross headed screwdriver No 1 Pozidrive 1 3 Antistatic precautions The electronics section of the product is sensitive to electrostatic discharge ESD which can cause Immediate or hidden long term damage It is impor...

Страница 2: ...ns Lithium battery Explosive risk corrosive fumes fire Handle appropriately avoid contact Biological hazard Radio frequency Physiological hazard Avoid close or prolonged exposure Radiation Do not touch the antenna during transmissions 1 7 Battery Kit contents Qty 1 x LED cap with gasket seal fitted Qty 1 x Battery with foam pad fitted Qty 2 x M3 Screws Qty 1 Date label Qty1 Clear Media Qty 1 Marki...

Страница 3: ...by pushing and holding the Off button the beacon should switch off after approximately 3 seconds NOTE Do not allow beacon to operate for longer than 15 seconds 2 2 Remove LED cap by removing 2 off Screws 2 3 Remove the battery The PCB foil insert do not need to be removed Note The battery should be disposed of in a sensible and considerate manner and in accordance with local regulations Also the L...

Страница 4: ...3998 Email service uk mcmurdogroup com Page 4 3 ASSEMBLY 3 1 Ensure the Foam Pad to the bottom of the cell pack 3 2 Ensure the replacement Sealing Gasket is fitted to the replacement LED cap assembly Note Ensure the gasket is seated correctly or product may fail the leak test 3 3 Ensure the PCB assembly is seated correctly ...

Страница 5: ...attery assembly into casing care should be taken to ensure foil insert is not damaged Position the wires as shown Connect the battery to the PCB 3 5 De press the battery counter reset button the LED and buzzer will operate for a duration of 1 second when indicating a successfully reset 3 6 Fit LED cap ensuring the wires are not trapped secure with 2 off Screws Tighten to 60cNm ...

Страница 6: ... test must be completed before the full function test Use hot water at 60 C 5 C 140 F 9 F Cooler water will not raise the air pressure enough Hotter Water may damage the unit 4 2 Instructions a It is best to remove lanyard if fitted b Remove the Red cap and deploy the antenna the unit will then turn on so turn it off before proceeding c Immerse the unit in the hot water d Dislodge ALL trapped air ...

Страница 7: ...ck traps water and should be left in the oven for at least 16 hours The oven is necessary as the battery will not dry out if left at room temperature CAUTION DO NOT EXCEED 70 C RISK OF EXPLOSION 5 LABELLING 5 1 Fit the new battery date over stick label and check that serial number and TX ID is still legible 6 FINAL ASSEMBLY 6 1 Fold the antenna around body reattach the activation cap The beacon wi...

Страница 8: ...to use a McMurdo M15 AIS receiver with AIS viewer running on Windows PC or similar AIS receive equipment to verify correct transmission after service 7 2 Instructions a Press and hold OFF for 10secs until 2sec long flash b Unit will flash every 1sec until GPS fix is achieved c After 1 minute a SART test message is sent which will be visible to all AIS systems within range d At the end of the test ...

Страница 9: ...igure of 8 knot Pull tight to hide the knot inside the tab like this b Fit the activation cap to the beacon note this will switch on the beacon so once fitted press and hold the off button to switch off the beacon c Function testing of the auto switch d Remove the activation cap and ensure the beacon switches on automatically switch off the beacon as above e Replace activation cap and switch off b...

Страница 10: ...oximately 80mm to allow for the removal of the activation cap Or 10 Rigged for semi automatic operating according to the lifejacket manufactures guidance notes When preparing the unit ready for lifejacket semi automatic activation it is not necessary to tie of the lanyard to the white section as this will be done by the lifejacket installer The free end of the longer length of the lanyard need not...

Отзывы: