background image

Please follow the instructions in this manual to obtain the optimum results from this unit.

We also recommend that you keep this manual handy for future reference.

O

P

E

R

A

T

IO

N

 M

A

N

U

A

L

PUBLIC ADDRESS SYSTEM

www.mcmelectronics.com

  SPEAKER ZONES

POWER

MIC 1

5

 0

 1

 2

 3

 4

 6

 7

 8

 9

10

BASS

0

-5

-4

-3

-2

-1

+1

+2

+3

+4

+5

TREBLE

0

-5

-4

-3

-2

-1

+1

+2

+3

+4

+5

5

 0

 1

 2

 3

 4

 6

 7

 8

 9

10

MIC 3

AUX 1

5

 0

 1

 2

 3

 4

 6

 7

 8

 9

10

AUX 2

MIC 1

MIC 2

5

 0

 1

 2

 3

 4

 6

 7

 8

 9

10

5

 0

 1

 2

 3

 4

 6

 7

 8

 9

10

MASTER

5

 0

 1

 2

 3

 4

 6

 7

 8

 9

10

ON

OFF

2

PROT

TEMP

4

6

8

10

12

OUTPUT LEVEL

1

2

3

4

5

ALL

MIXER AMPLIFIER

ZONE MIXER AMPLIFIER
MODEL ZPA-60
MODEL ZPA-120

Содержание ZPA-120

Страница 1: ...www mcmelectronics com SPEAKER ZONES POWER MIC 1 5 0 1 2 3 4 6 7 8 9 10 BASS 0 5 4 3 2 1 1 2 3 4 5 TREBLE 0 5 4 3 2 1 1 2 3 4 5 5 0 1 2 3 4 6 7 8 9 10 MIC 3 AUX 1 5 0 1 2 3 4 6 7 8 9 10 AUX 2 MIC 1 MIC 2 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 MASTER 5 0 1 2 3 4 6 7 8 9 10 ON OFF 2 PROT TEMP 4 6 8 10 12 OUTPUT LEVEL 1 2 3 4 5 ALL MIXER AMPLIFIER ZONE MIXER AMPLIFIER MODEL ZPA 60 MODEL ZPA 12...

Страница 2: ...RIPTION 5 3 FEATURES 5 4 NOMENCLATURE AND FUNCTIONS 4 1 Front Panel 2U 6 4 2 Rear Panel 2U 7 5 CONNECTIONS 5 1 Speaker Connections 5 2 XLR Connections 6 7 APPLICATIONS 10 8 BLOCK DIAGRAM 11 9 SPECIFICATIONS 12 10 DIMENSIONAL DIAGRAM 13 8 8 9 MACHINE OPERATION ...

Страница 3: ... cord as doing so may result in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth terminal to avoid electric shock Never ground to a gas pipe as a catastrophic disaster may result Avoid installing or ...

Страница 4: ... shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to minimum position before power is switched on Loud noise produced at high volume when power is switched on can impai...

Страница 5: ...att rated output 100V 70V line transformer isolated speaker outputs low impedance 4 16 ohms speaker outputs One EMC priority input Two aux input and two line input Two balanced mic inputs and three unbalanced microphone inputs EMC input with priority over all other inputs except MIC 1 AUX MIC Bass Treble and Master volume control MIC 1 mute level control Power and protection indicators and 6 outpu...

Страница 6: ...ontrols all size of input signal level 7 POWER SWITCH On top of the opening Power Press the end power shut down 8 POWER The power LED lights when it is turned on the power LED lights out when it is turn off 9 LEVEL INDICATORS Level meters 6 output level indicators 10 PROT When the machine is in protection status this indicator will be lit in normal operation status the LED is off If the product is...

Страница 7: ...to connect the speaker with 70V 100V terminal is used to connect the speaker with 100V Once there is signal to the emergency alarm signal input the equipment will play the music signal in this channel as priority except MIC1 When turning the mute potentiometer to the right it is at the maximum mute whereas it is the minimum 18 MIC2 MIC3 MIC Unbalanced inputs 19 MIC2 LINE MIC3 LINE MIC2 MIC3 20 AUX...

Страница 8: ...00V LINE 70V 100V COM 4 16 70V LINE 5 1 SPEAKER CONNECTIONS 5 2 XLR CONNECTIONS 4 16 ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 100V LINE 100V LINE100V LINE100V LINE 100V LINE 70V 8 60W 120W 166 7 83 3 60W 120W 81 6 40 8 COM 70V COM 70V COM 70V COM 70V COM 70V ...

Страница 9: ...ors work together If voltage is 70V 100V the speakers must be with transformer and make sure the total power wattage of speaker is 15 less than the power wattage of amplifier GUIDANCE OF EXCLUDING ERRORS No voice output in normal condition All the wires are connected well but no voice output Cause 1 No power or wrong plug connection 2 Fuse is burned 3 Volume is town off 4 No input signal Power on ...

Страница 10: ... INPUT MIC2 MIC3 LINE INPUT COM COM MIC2 MIC3 MIC 2 MIC 3 MIC 2 XLR GAIN MIC 3 XLR GAIN MIC 2 MIC 3 USE ONLY WITHA 250V FUSE ALARM IN ALARM OUT MIC IN REC IN AUDIO OUT R R L L LOOP ANTENNA Fm75 ANTENNA AM GND 1 2 3 USE ONLY WITHA 250V FUSE INPUTS LINK COM 4 16 70V 100V OUTPUT COM COM GND LIFT CH5 CH4 CH3 CH2 CH1 COM 70V COM 70V COM 70V COM 70V COM 70V ...

Страница 11: ...MIX OUT 100V 70V 4 TO PA BASS TREBLE VOLUME PROTECT LEVEL INDICATOR POWER Z AC 120V 60Hz PT EB MIC1 COM MUTE EB EMC EB EB EB EB AUX1 EB AUX2 MUTE MASTER MIC3 LINE1 LINE1 MIC2 8 BLOCK DIAGRAM 11 ...

Страница 12: ...nals with 0 30dB Individual gain controls power switch Power LED LED level meter protect AC fuse short circuit and high temperature DIMENSION mm NET WEIGHT GROSS WEIGHT 484X335X88 POWER CONSUMPTION POWER REQUIREMENTS 60W 7 4Kg 7 1Kg 100W 120W 120V 60Hz 9 7Kg 9 3Kg 200W Bass 10dB at 100Hz Treble 10dB at 10KHz MIC 1 5mV 600 Ohms Unbalanced TRS input MIC 2 3 5mV 600 Ohms Unbalanced TRS XLR input MIC2...

Страница 13: ... 5 SPEAKERZONES ALL COM 4 16 70V 100V EMC INPUT 1 2 3 1 2 3 MUTE CH5 CH4 CH3 CH2 CH1 MIC 2 48V PHANTOM MIC2 MIC3 MIC 2 MIC 3 MIC 3 48V PHANTOM AUX2 INPUT MIX OUT AUX1 INPUT MIC2 MIC3 LINE INPUT OUTPUT DC 24V MIC 2 XLR GAIN MIC 3 XLR GAIN POWER MIC1 5 0 1 2 3 4 6 7 8 9 10 BASS 0 5 4 3 2 1 1 2 3 4 5 TREBLE 0 5 4 3 2 1 1 2 3 4 5 5 0 1 2 3 4 6 7 8 9 10 MIC 3 AUX 1 5 0 1 2 3 4 6 7 8 9 10 AUX 2 MIC 1 MI...

Страница 14: ...f purchase This warranty is limited to manufacturer defects in either materials or workmanship MCM Electronics or any other worldwide divisions of Premier Farnell PLC are not responsible for any consequential or inconsequential damage to any other component structure or the cost of installation or removal of said items For questions or specific information regarding warranty replacement or repair ...

Отзывы: